Sale!

5SHX1960L0006 3BHB016120R0002 Input/output module ABB

Original price was: $1,888.00.Current price is: $1,688.00.

Model:5SHX1960L0006 3BHB016120R0002

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

5SHX1960L0006 3BHB016120R0002 Input/output module ABB
5SHX1960L0006 3BHB016120R0002 Input/output module ABB
5SHX1960L0006 3BHB016120R0002 Input/output module ABB Product details:
5SHX1960L0006 3BHB016120R0002 is an interface communication module from ABB, with product model 5SHX1960L0006 3BHB016120R0002. This module is commonly used in industrial automation systems,
especially in the field of process control. Here are some possible application and product operation areas:
Industrial automation: Th5SHX1960L0006 3BHB016120R0002 communication module may be used to communicate with other automation equipment, control systems,
or sensors to achieve automation and integration of industrial production lines.
Process control: This module may be used to monitor and control various processes, such as chemical plants, power plants, pharmaceutical plants,
etc. Through communication with other devices, it can achieve data exchange and control instruction transmission.
PLC (Programmable Logic Controller) system5SHX1960L0006 3BHB016120R0002 may be integrated into the PLC system for communication with other PLC modules or
external devices, achieving centralized management of the entire control system.
Data collection and monitoring: In the data collection system5SHX1960L0006 3BHB016120R0002 can be used to obtain data from various sensors and devices,
and transmit this data to the monitoring system for real-time monitoring and analysis.
Remote monitoring and operation: Through collaborative work with other communication modules5SHX1960L0006 3BHB016120R0002 may support remote monitoring and operation,

allowing operators to monitor and control the production process from different locations.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

VMIVME-7614-132350-017614-132 D   GE  Turbine Control PCB board
MMS6110  EPRO  Axial vibration measurement module
3VWWZ036CD001  GE
05701-A-0330  HONEYWELL  HIGH INTEGRITY CARD
PI3381  TRICONEX   Pulse input card
531X307LTBAJG1 GE  LAN Terminal Board 531X Series
IC660BBD101 IC660EBD101  GE  Input/Output Block
DS200LDCCH1AGA  GE  Drive Control/LAN Communications Board
P0922YU FPS400-24 FOXBORO  Power Supply
IS210AEBIH3BED  GE
IOP114  METSO  TC/MV INPUT MODULE REV D/E D526316
G2010 A 10.4ST ABB Genera Industrial Panel Computer
SAC-RL100-M11T  AUTOTECH CONTROLS  encoder
CP451-50  YOKOGAWA  Processor Module
EST0240Z05WBX00 YAMATAKE  touch screen
UAC389AE02 HIEE300888R0002 ABB  PCB BOARD
PM783F 3BDH000364R0002 ABB CPU Module
IPMC761-001  MOTOROLA  Multifunction rear I/O PMC module
81001-450-53-R  MITSUBISHI  DRIVE MODULE
SR745-W2-P5-G5-HI-A  GE  transformer management relay
1756-IF16A  Allen-Bradley   ControlLogix module
IPMC7616E-002  MOTOROLA  Circuit Card Assembly
WR-D4007  RELIANCE  POWER SUPPLY CARD II
PM3326B-6-1-2-E 80026-529-01  PIONEER MAGNETICS  POWER SUPPLY
IC693PWR322F GE standard power supply
SCXI-1160 NI  General Purpose Relay Switch Module
2481  TRICONEX 2481  Output module substrate
2401  TRICONEX 2401  communication module
2101  TRICONEX 2101  Digital Input Output Module
216EA62 1MRB150083R1F 1MRB178066R1F ABB Analog Input
560CMU05 ABB Communication unit (CMU) for RTU560
ANC-100E AN-X2-AB-DHRIO  PROSOFT  Ethernet DH+ converter
8610-FT-NA  EATON    NON-ARCING FIELD TERMINAL
SCM-1  DEIF  encoder
2351 TRICONEX 2351  Et200s Analog Input
UFC721BE101 3BHE021889R0101 ABB ADCVI Board
WESDAC D20 A  GE  Substation controller
PPC902AE101 3BHE010751R0101  ABB  Control Board
IC660ELB912J  GE   Genius Network Interface module
64SD1-08KRF1-13  NAI  Multifunctional data board

Reviews

There are no reviews yet.

Be the first to review “5SHX1960L0006 3BHB016120R0002 Input/output module ABB”

Your email address will not be published. Required fields are marked *