Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
F5-MEC Flowserve valve positioner
D20 EME GE ETHERNET/MEMORY
AUE-1108 KOLLMORGEN Robot system spare parts
07DC91C GJR5251400R0202 ABB Digital input and output unit
VE3006 12P3439X012 G6450081A KJ2003X1-BB1 EMERSON controller
MAESTRO 60X714 MINI Dc driver
416NHM30032A Schneider volt adapter
369-HI-R-M-F-E-H-E GE Motor Management Relay
140CRP31200 Schneider ETHERNET RIO HEAD
07EA90-SI GJR5251200R0101 ABB Analog Input Module
416NHM30030 Schneider Modbus Plus PCI Bus Adapter with Plug and Play Capability
UFC911B108 3BHE037864R0108 ABB PROCESSOR MODULE
UFC911B106 3BHE037864R0106 ABB PROCESSOR MODULE
UCD208A101 3BHE020018R0101 ABB PROCESSOR MODULE
GCC960C103 3BHE033067R0103 ABB CPU rectifier
UAD154A 3BHE026866R0101 ABB PROCESSOR MODULE
SCM4.1 2044230022A 2044230020D DEIF control panel
TB820-2V2 3BSE013209R1 ABB PROCESSOR MODULE
P0926GH FOXBORO CHANNEL COMMUNICATION TERMINAL
IOM4.2 2044230041E 2044230040H DEIF PCB CARD
3BHE024747R0101 ABB Analog Output Modules
LCNP4E 51405098-100 Honeywell Card
IS200DTAOH1ABA IS210DTAOH1AA GE printed circuit board
IS200DTAIH1ABB IS210DTAOH1AA GE printed circuit board
TCSESM043F2CS0 Schneider Ethernet TCP/IP Managed Switch
TSXMRPC002M Schneider CONFIGURABLE SRAM MEMORY EXTENSION
ENK32 ABB EAE Ethernet Module
1336F-BRF50-AA-EN-HAS2 Allen-Bradley 3.7 kilowatt drive
SIOC086406-002 ABB Servo Controller
SCXI-1325 NI Screw Terminal Block
SCXI-1326 NI High-Voltage Terminal Block
IS230TNCIH4C GE Mark VI Printed Circuit Board
IS230TBAIH2C GE ANALOG I/O DIN RAIL MOD.
IS230SRTDH2A GE Terminal assembly
ECPSR086370-001 ABB DRIVER BOARD
51202329-606 Honeywell I/O Link Gray Header Cable
490NRP25400 Schneider Fiber Optic Repeaters
140CPU43412A Schneider PROCESSOR
TAC-311DG DEIF Single-function transducer
1900/27 Bently Nevada Vibration Monitor
04220FL11232A GE RXI CONTROLLER
Reviews
There are no reviews yet.