Sale!

8C-PCNT02 Output module Honeywell

Original price was: $1,888.00.Current price is: $1,688.00.

Model:8C-PCNT02

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: 8C-PCNT02
Brand: Honeywell
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
8C-PCNT02 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
8C-PCNT02 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: 8C-PCNT02 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install 8C-PCNT02 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating 8C-PCNT02 to ensure proper use.
Product Introduction
8C-PCNT02 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

https://www.xmamazon.com

https://www.xmamazon.com

Home

Home

https://www.plcdcs.com/

www.module-plc.com/

https://www.ymgk.com

ABB CI615 3BHT300024R1 CI615K01 3BSE000756R1 Bus expansion module
ABB CI560 3BUC980002R1 Interface module Advant OCS TRIO inventory
ABB CI532V09 3BUP001190R1 Submodule AccuRay CI534V02 3BSE010700R1
ABB CI532V01 3BSE003826R1 CI532V02 PLC Interface module CI532V5
ABB CI522AK04 3BSE018451R1 CI522AK06 3BSE018453R1 Communication Module
ABB CI531 RS-232 interface submodule 3BSE003825R1
ABB CI526 3BSE006085R1 System Interface module CI526V1 3BSE012870R1
ABB CI 930F Communication port 3BDH001010R0001 3BDH001010R0002 CI930F
ABB Bailey network processing module INNPM11 Infi90
ABB Bailey INSIM01 Net90 serial interface module
ABB Bailey INSEM11 Board card
ABB ACU controller for IRB52 3HNA027980-001 paint spray control
ABB CI522 23BSE012790R1 Interface module CI522A 3BSE018283R1 PLC
ABB Bailey Network Processing module INNPM11 Infi90 Symphony Inventory Bailey
ABB Bailey INTKM01 Serial interface module Net90 Infi90 inventory
ABB AC900F Controller Unit PM904F 3BDH001002R0001 Processor module
ABB AC70 processor module PM810V2 S800CPU 3BSE013220R1 Inventory
ABB AC800PEC PC D230 A exciter control module AC800PEC PCD235 is available
ABB AC460 Controller Card Rack RF523 3BSE006802R1 Advant OCS rack
ABB AC 800M controller module PM861AK01 3BSE018157R1 PM861A
ABB 7 “Touch Screen PP874M 3BSE069279R1 Solid Marine Certification Panel Black
ABB 5SHY5055L0002 IGCT High Voltage Frequency Conversion 3BHE019719R0101 GVC736BE101
ABB 5SHY 4045L0004 Thyristor 3BHB021400R0002 IGCT module
ABB 5SHY3545L0010 3BHB013088R0001 SCR Module 5SHY 3545L0010
ABB 5SHY 354510009 High voltage Converter Board 3BHB013085R0001
PP871 3BSE069270R2 4.3″ Panel 800 Touch Screen
ABB AC 800M controller module PM864AK01-EA
ABB 3BHL000387P0101 High voltage converter power module
PP886H 3BSE069297R1 ABB 15″ Rugged Touch panel
ABB PP882 3BSE069275R1 12.1″ Human-computer interaction screen
ABB standard Touch screen PP877 3BSE069272R2
ABB 88FN02B-E GJR2370800R0100 Communication module
ABB 5SHY3545L0010 3BHB013088R0001 SCR Module 5SHY 3545L0010
NDBU-85C ABB Thyristor Power Converters
NDBU-95 ABB  Thyristor Power Converters
LD SYN-01 SYNCH ABB
GD C806 B02 GATE DRIVE + ACL UNIT GDC806B02
UF C765 AE102 ABB EAF-BOARD COATED UFC765AE102

Reviews

There are no reviews yet.

Be the first to review “8C-PCNT02 Output module Honeywell”

Your email address will not be published. Required fields are marked *