Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
SPDSO15 Digital output module
SPDSO14 digital output module
SPDSM04 Pulse In Module
SPDSI22 Digital input module
SPDSI14 Digital input module
SPDSI13 Digital Slave Input Module
SPCIS22 Control I/O Module
SPASO11 AO Module 14 CH, Supports 4-20mA, 1-5V
SPASI23 AI Module
SPTKM01 SOE Time Keeper Master
SPSEM11 SOE Master Module
SPNPM22 Network Processor Module
SPNIS21 Network Interface Module
SPIPT800 PN800 Transfer Module
SPIIT13 Local Transfer Mod
SPIIT12 Remote Transfer Mod
SPIIL02-L Local interface suite
SPIET800 Ethernet CIU Transfer Module
SPICT13A S+ Infi-net to Computer Interface Module
SPICI800 Ethernet CIU Kit
SPCPM02 RS-232 Serial interface
SPBRC410 Modbus Indicates the controller of the TCP interface
SPBRC400 Controller with Expanded Memory
SPBRC300 Controller module
SPBLK01 Control System module
PBA800 Process Bus Adaptor HN800
INTKM01 time Keeper Master Module
INSEM11 Sequence of Events Master Module
INNPM22 Network Processor Module
INNIS21 Network Interface Slave module
INIET800 Communication Module
INICT13A HR series controller
IMBLK01 Blank Faceplate HR Series
KEBA FM 265/A Profibus Interface module of the slave station
FC-TSHART-1620M Analog input module
FC-TSAI-1620M Analog input module
F7553 Coupling Module HIMA
HIMA 8-Channel Output Module F3330
HIMA F3236 igital Input Module
Flowserve F5-MEC-420 Feedback unit valve positioner
Mark V DS200DCFBG1BLC Power Supply Board
Reviews
There are no reviews yet.