Description
hardware flow control. It is an ideal choice in the field of industrial automation.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
ZYGO 8070-0102-02
ZYGO 8070-0278-01 SEM-I-1231=9B48
ZYGO 7034 8040-0101-01
ZYGO ZMI-2002 8020-0211-1-J
JDSU 2211-015SLBD
JDSU 2111A-10SLHP
JDSU 185P-F1 209
JDSU 2114B-30SLT
JDSU 2214-30SLQRT
JDSU 2214-20SLUP
JDSU 2214-25MLUP
JDSU 2214-25MLVP
JDSU 2214-30SLQT
JDSU 2213-75TSLKTD
JDSU 2213-75TSLKTA
JDSU 2213-75-TSLKTB -LASER-4-AMPS- 500-MW-487-9NM
JDSU 2213-75SLR
JDSU 2213-15VL
JDSU 2213-75TSLKTB
JDSU 2214-30SLOTT
JDSU 2214-30SLQTA
“WOODWARD 5501-471 NETCON SIO MODULE”
A-B 1394C-SJT10-C-RL
ABB SYN5202A
ABB SYN5202-0277
ABB SYN5202-0271
ABB 3BHB006714R0277
ABB SYN5201A-Z V277
ABB SYN5201A-Z V277 3BHB006714R0277
ABB 3BHB006714R0217
ABB SYN5201A-Z V217 3BHB006714R0217
ABB SYN5200a-Z 3BHB006713R0217
ABB 3BHB006713R0217
ABB SYNCHROTACT 5 3BHB006713R0217
ABB SYN5200a-Z,V217 SYNCHROTACT5
ABB SYNCHROTACT 5
ABB SYN5200a-Z V217
ABB SYN5200a-Z
ABB SYN5200a-Z,V217 SYNCHROTACT5 3BHB006713R0217
MOTOROLA 84-W8324F01B
MOTOROLA 01-W3324F 84-W8324F01B
MOTOROLA 01-W3324F
MOTOROLA 30-W2960B01A
MOTOROLA BOARD 466023
MOTOROLA CPCI-6020TM
MOTOROLA FAB 0340-1049
MOTOROLA CPU3640
MOTOROLA FLN3524A CPU3640
MOTOROLA FLN3524A
MOTOROLA ACE3600
MOTOROLA FLN4234A ACE3600
MOTOROLA FLN4234A
MOTOROLA CPU3680
MOTOROLA FLN4234A CPU3680
MOTOROLA FLN4234A
MOTOROLA IPMC7616E-002
MOTOROLA 3921/01-W2761E01B
MOTOROLA MCP750 3921/01-W2761E01B
MOTOROLA MCP750
MOTOROLA MPC2004
MOTOROLA MVME 374-1
MOTOROLA MVME-147A
MOTOROLA MVME147S-1
MOTOROLA MVME147SRF
MOTOROLA MVME162-012
Reviews
There are no reviews yet.