Description
hardware flow control. It is an ideal choice in the field of industrial automation.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
G122-829-001 MOOG servo amplifier
IC660ELB912G GE Genius I/O
IC693APU300K GE High-Speed Counter (HSC) module
IC693APU301 GE Axis Positioning Module
IC693CMM301 GE Genius communication module
IC693CPU331 GE Single slot CPU module
IC693CPU341 GE Single slot CPU module
IC693DNM200 GE DeviceNet Master Module
IC693PWR330G GE High capacity power supply module
IC697MEM717C GE CMOS extended memory
IS200VAICH1DAB GE Mark VI printed circuit board
IS200VCRCH1B GE Mark VI printed circuit board
KX8974c V24 HIEE320606R1 ABB Interface card
MDX61B0015-5A3-4-0T Movidrive Inverter Unit
PP846A 3BSE042238R2 ABB Function key panel
PPC380AE102 HIEE300885R0102 ABB power-supply module
HE700GEN200 GE Genius interface module
T1023-07C HIER466513P111 TRACO POWER power-supply module
T1032-07C HIER466688P111 TRACO POWER power-supply module
T8310 ICS TRIPLEX TMR Expander Processor
T8403 ICS TRIPLEX Trusted TMR 24Vdc Digital Input Module
UNS0007A-P V1 HIEE305098R0001 HIEE410730P201 ABB Ignition plate
IS220PPROH1A GE Mark VI component
VE3008 12P6381X032 KJ2005X1-MQ1 controller module
VME-SSI AVMESSI Encoder module
VMIVME-5565-110000 GE Reflective Memory Node Card
VMIVME7740-841 GE single board computer
XTB750B01 HUCD420038R0001 ABB Interface Module
XVC517AE02 ABB PLC control panel
ZT372a-E GJR2237800R1 HE663909-31828 ABB procontrol-module
369-HI-R-M-0-0-0-0 GE Motor Management Digital Relay
531X305NTBANG1 GE NTB/3TB Terminal Board 531X Series
573-935-202C VIBRO PLC module
567LH-DP24 REOTRON Drive
3708EN TRICONEX Outpout Module
9907-1183 Woodward Digital governor
125760-01 Bently Nevada Data Manager I/O Module
135613-02 Bently Nevada High Temperature Case Expansion Transducer Assembly
CB06561 PRD-B040SSlz-62 KOLLMORGEN Servo driver
CI541V1 3BSE014666R1 ABB rofibus Interface Submodule
DS200SDCIG1ABA GE RST Analog I/O Board
DS200TCQCG1BKG GE RST Overflow Board
DS215TCQAG1BZZ01A GE RST Analog I/O Board
DSMB-01C ABB power panel
DT602 GJR2911200R1 ABB DCS module
DT680E GJR2923100R1 ABB PLC module
EMDR RAYCHEM Control Unit
FSA80 Danaher Servo driver
FTA-544 17-550544-001B HONEYWELL Output Module
HE700GEN200C GE Control interface module
FTA-554 17-550554-001 HONEYWELL Output Module
Reviews
There are no reviews yet.