Sale!

DS200SIOBH1AAA Boards & Turbine Control Module

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200SIOBH1AAA

Первоначальная гарантия на один год.
DS200SIOBH1AAA Параметры

DS200SIOBH1AAA Размер 30 * 20 * 30
DS200SIOBH1AAA Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

DSTS106 3BSE007287R1 Trigger pulse Generator cassette backup regulator
DI650 3BHT300025R1 Digital input 32 channels
DSTS105 3BSE007286R1 is used to simulate a backup regulator
3500/92-02-01-00 Communication gateway
TC515V2 3BSE013284R1 AF100 Twisted pair repeater
DSAI155A 3BSE014162R1 thermocouple module
TC512V1 3BSE018059R1 RS485 Twisted pair modem
DSAO130A 3BSE018294R1 Analog output board 16 channels
DSTA155P 3BSE018323R1 Connect unit 14 thermocouple
DSTA002B 3BSE018317R1 Analog input board connection unit
DSTA135 3BSE018315R1 input board
DSTD190V1 3BSE018314R1 Connects to unit 32 Ch
DSTA001B 3BSE018316R1 Analog long connection unit
DSTA001B 3BSE018316R1 Analog long connection unit
DSTA181 3BSE018312R1 connection unit for simulation
DSTA156B 3BSE018310R1 Connect unit 32 Ch
CI522AK04 3BSE018451R1 Communication module
CI522AK02 3BSE018449R1 Communication bus module
CI522AK01 3BSE018448R1 Field Bus interface module
CI522AK03 3BSE018450R1 Communication module
DSTD108P 3BSE018333R1 Connects to Unit 8 Ch
DSTD108LP 3BSE018335R1 connection unit with 8 relays
DSTD196P 3BSE018332R1 Connects to the Unit 8 Ch S100 I/O terminal unit
DSTD109P 3BSE018327R1 Connects to Unit 8 Ch S100 I/O terminal unit
ABB TC560V2 3BSE022178R1 Optical Modem
T8110B ICS Triplex Trusted TMR Processor
Enterasys SSA-G1018-0652 switchboard
SRFC4620C Inverter filter board
SR469-P5-HI-A20-E-H Motor management relay
SINT4611C Main circuit interface board
SDCS-PIN48-SD PULSE TRANSFORMER BOARD
SCXI-1302 Terminal block
SCXI-1160 General-Purpose Switch Module for SCXI
SCXI-1102 Voltage Input Module for SCXI
SCXI-1100 Voltage Input Module for SCXI
SC560 3BSE008105R1 Submodule Carrier incl local CPU
RXIIK 4 1MRK001643-AA Negative sequence overcurrent relay
RXEDK 2H 1MRK000841-KA Time Over/Under Voltage Relay
RVAR-5612 68260850 VARISTOR UNIT
RMIO-11C 68789010 CONTROL BOARD
REXROTH LT304  SN:882000119
REX B871NN-CS1B1 controller
REX010 HESG324426R0001 HESG324389 Earth Fault Protection Unit
PPD113 PPD103B101 3BHE020455R0101 3BHE023784R2630 controller
PP836 3BSE042237R1 PP836 Operator Panel
PP835A 3BSE042234R2 Touch Panel, 6.5″
SAIA PCD4.D1XX 463665500  Communication
PCD2.M110 Central processing units

Reviews

There are no reviews yet.

Be the first to review “DS200SIOBH1AAA Boards & Turbine Control Module”

Your email address will not be published. Required fields are marked *