Sale!

IC695CPE310-ABAB Horner Electric

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIC695CPE310-ABAB

Первоначальная гарантия на один год.
IC695CPE310-ABAB Параметры

IC695CPE310-ABAB Размер 30 * 20 * 30
IC695CPE310-ABAB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

IC695CPE310-ABAB Horner Electric
IC695CPE310-ABAB Horner Electric
IC695CPE310-ABAB Horner Electric Product details:

IC695CPE310-ABAB Technical Manual

IC695CPE310-ABAB Weight:1.8KG
IC695CPE310-ABAB Size: 20* 20 * 10cm
IC695CPE310-ABAB instructions
IC695CPE310-ABAB PDF
Многие продукты еще не на полке, пожалуйста, свяжитесь с нами, если вам нужно больше продуктов
 
. Если модель продукта не совпадает с представленной картиной, следует использовать модель. Свяжитесь с нами для получения фотографий конкретных продуктов,
Мы устроим фотосессию на складе.
 
. У нас есть 16 общих складов по всему миру, поэтому поймите, что иногда может потребоваться несколько часов, чтобы точно вернуть их вам. Конечно,
Мы ответим на ваши вопросы как можно скорее.
IC695CPE310-ABAB  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
 
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и
высотой 3U, расположенный в раме управления под DSPX.
 
IC695CPE310-ABAB  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
 
Применение данных
 
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
 
Соединитель
 
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IC695CPE310-ABAB :
 
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
 
• Ввод тока на панели EDCF в аэропорту постоянного тока
 
Ввод напряжения возбудителя EDCF (необязательно)
 
Ввод тока в возбудитель EDCF (необязательно)
 
• Ввод напряжения в детектор заземления
 
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

http://www.dcsmodule.ru/



Основные продукты:

ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.

General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.

Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.

Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.

Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.

Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.

Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.

Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.

Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.

Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.

Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.

Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.

Больше…

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

 

Display operation panel CI854AK01 3BSE030220R1
Display operation panel CI854AK01
Display operation panel CI854AK01
Display operation panel CI854AK01
Display operation panel CI854AK01
Display operation panel CI854A-eA 3BSE030221R2
Display operation panel CI854A/3BSE030221R1
Display operation panel CI854A 3BSE030221R1
Display operation panel CI854A 3BSE030221R1
Display operation panel CI854A 3BSE030220R1
Display operation panel CI854A
Display operation panel CI854A
Display operation panel CI854A
Display operation panel CI854 3BSE025349R1
Display operation panel CI854 3BSE025347R1
Display operation panel CI854
Display operation panel CI854
Display operation panel CI853K01
Display operation panel CI853K01
Display operation panel CI853K01
Display operation panel CI853K01
Display operation panel CI853
Display operation panel CI851K01 3BSE018101R1
Display operation panel CI851K01
Display operation panel CI851
Display operation panel CI840kit 3BSE031694R4000
Display operation panel CI840A 3BSE041882R1
Display operation panel CI840A
Display operation panel CI840A
Display operation panel CI840A
Display operation panel CI840A
Display operation panel CI840
Display operation panel CI830 3BSE020773R1401
Display operation panel CI830
Display operation panel CI830
Display operation panel CI820V1
Display operation panel CI820-2
Display operation panel CI820-1
Display operation panel CI820
Display operation panel CI810V2
Display operation panel CI810V1
Display operation panel CI810V1
Display operation panel CI810B 3BSE020520R1
Display operation panel CI810B
Display operation panel CI810B
Display operation panel CI810B
Display operation panel CI810A
Display operation panel CI810
Display operation panel CI801kit
Display operation panel CI801-eA
Display operation panel CI801-2
Display operation panel CI801
Display operation panel CI801
Display operation panel CI801
Display operation panel CI773F 3BDH000395R0005
Display operation panel CI773F
Display operation panel CI773F
Display operation panel CI773
Display operation panel CI741F
Display operation panel CI687K01
Display operation panel CI627A 3BSE017457R1
Display operation panel CI627A 3BSE008799R1
Display operation panel CI627A
Display operation panel CI627 3BSE009799R1
Display operation panel CI627
Display operation panel CI627
Display operation panel CI626V1
Display operation panel CI626A 3BSE005029R1
Display operation panel CI626
Display operation panel CI615
Display operation panel CI610
Display operation panel CI570 3BSE001440R1
Display operation panel CI547
Display operation panel CI546 3BSE012545R1
Display operation panel CI546 3BSE012545R1
Display operation panel CI541V1 3BSE014666R1
Display operation panel CI540 3BSE001077R1
Display operation panel CI535V30 3BSE022162R1
Display operation panel CI534V02 3BSE010700R1
Display operation panel CI532V09
Display operation panel CI532V05 3BSE007297R1
Display operation panel CI532V03
Display operation panel CI522A 3BSE018283R1
Display operation panel CI522A 3BSE018283R1
Display operation panel CI522A
Display operation panel CI520V1
Display operation panel CD722F
Display operation panel CB810
Display operation panel CB801 3BSE042245R1
Display operation panel CB801
Display operation panel CB801
Display operation panel CB801
Display operation panel CB220S
Display operation panel CB220N

· Многие продукты еще не доступны, пожалуйста, свяжитесь с нами, чтобы узнать больше о продуктах
 
 
• Если модель продукта не совпадает с представленной картиной, следует использовать модель. Пожалуйста, свяжитесь с нами,
мы организуем фото на складе, чтобы подтвердить
 
 
У нас есть глобальные запасы и 16 региональных складов в 6 странах, поэтому поймите, что иногда может потребоваться несколько часов,
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.

Reviews

There are no reviews yet.

Be the first to review “IC695CPE310-ABAB Horner Electric”

Your email address will not be published. Required fields are marked *