Description
hardware flow control. It is an ideal choice in the field of industrial automation.
(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;
(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;
(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.
4 Inverter operation settings
After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.
After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.
4.1 Basic settings
(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.
(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.
(3) 51.03—This parameter is Profibu
The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.
(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]
4.2 Connection of process parameters
The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.
(1) PZD value sent from PLC to transmission inverter
PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;
PZD2—frequency setting value of the inverter.
(2) PZD value sent from the transmission inverter to the PLC
PZD1—status word, such as alarm, fault and other inverter operating status;
PZD2—actual speed value, current actual value, etc. of the frequency converter.
5 Conclusion
After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.
New technology from Swiss ABB Group: Complete car charging in 15 seconds
This technology can charge a car in 15 seconds
The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.
ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.
The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.
ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.
ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
4508 High Speed Channel Interface Module (HIM)
8105 TRICONEX 8105 I/O empty slot plate
TRICONEX PS8310 Interface module
PCD232A101 3BHE022293R0101 ABB Excitation system
4400 TRICOENX 4400 Safety Management Module (SMM)
9001 I/O communication bus extension cable
8306A Expansion / RXM Rack Power Supply, 24VDC
3500/25 149369-01 BENTLY
8102 Remote Expansion Rack
8305A Expansion / RXM Rack Power Supply, 115VAC/DC
PR6423/00R-010+CON021 EPRO System displacement module
8307A Expansion / RXM Rack Power Supply, 230VACTRICONEX TRICON 8101 Expansion Rack
PR6423/00R-131+CON041 EPRO Vibration sensor
PFCL201C pillow block tension meter vertical load cell
PFEA111 conventional control unit
PFEL113: With DP port, can connect to 4 indenters
PFEL112: With DP port, it can connect two indenters
PFEL111: No DP port and can be connected to two indenters
PFCL301E mini paper tension vertical load cell
PFTL301E mini paper tension horizontal load cell
PFRL101D radial load cell
PR6423/10R-131+CON041 EPRO Pressure transducer
PFRL101C radial load cell
PFRL101A radial load cell
PR6423/10R-111+CON031 EPRO Robot control card
PR6423/008-110+CON021 EPRO sensor
PFTL201C 50KN 3BSE007913R50 Weight bearing sensor
DS200DCFBG1BLC GE Dc governor control board
CON011 9200-00001 EPRO cable
GPIB-140A 186135G-01 NI Memory storage module
SCYC51020 58052582G ABB Thermal resistance input module
PM865K01 3BSE031151R1 ABB Thermal resistance input module
FBM230 P0926GU FOXBORO Communication module
TRICONEX 8111N rack
TRICONEX 3501TN2 Servo control system
TRICONEX 3008N Digital signal output module
TRICONEX 8310N2 Converter main control board
TRICONEX 4352AN Rectifier module
DSDP140A Robot drive power supply
UFC721BE101 3BHE021889R0101 Technical parameters
PPC380AE01 HIEE300885R0001 PLC controller
UFC718AE01 HIEE300936R0001 ABB Safety control unit
UFC719AE01 3BHB003041R0001 ABB Control system
Reviews
There are no reviews yet.