Description
IS200EMIOH1A Reliable Turbine Control Solutions
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
SAIA MURTEN PCD2.M110 CONTROL DEVICE
SAIA MURTEN PCD2.C100 CONTROL DEVICE
SAIA BURGESS PCD2.M110 CONTROL DEVICE
SABROE RMM SLAVE CARDS REFRIGERATION CONTROL SYSTEM
SAACKE CMFS1-T09-B BURNER CONTROL UNIT
SAACKE BOILER CONTROL UNIT SAACKE IMS INTEGRATED MANAGEMENT SYSTEM
SAACKE BAC-UV BURNER CONTROL UNIT
ROLLS-ROYCE W-1440-00-07 STEERING GEAR CONTROL PANEL
ROLLS-ROYCE MARINE DTL-NT-318-106 WINCH CONTROL SYSTEM
ROLLS-ROYCE MARINE AQM-STBD CONTROL PANEL
ROLLS ROYCE MARINE WINCON-ULSTEIN-MASTER-DISPLAY CONTROL PANEL
ROLLS ROYCE MARINE ULSTEIN-WINCH-SPEED-LEVER CONTROL PANEL
ROLLS ROYCE DECK MACHINERY MPC-300-A7029099 TERMINAL CONTROLLER UNIT
REXROTH VT-11013-12-7087-06W30-MNR-R900010960 CONTROL UNIT
REXROTH MNR-3460690120-HW-D-SW-O3WG-MAREX-OS-III MPC CABINET
REXROTH MAREX-OS-II-MPC-MODULAR-3460690000 CONTROL UNIT
REXROTH MANNESMANN-VT11025-16 AMPLIFIER MODULE
REXROTH 7291-FD-14W14-MNR-R419300356 CONTROL PANEL
REXROTH 7291-FD-09W31-MNR-R417000517 CONTROL PANEL
ABB 216AB61 HESG216881/B
ABB 216AB61 HESG324013R100
ABB 216AB61 HESG324013R100 / HESG216881/B
ABB 216AB61
ABB 216EA61b
GE VMIVME-5565-010000
GE VMIVME-5565-110000
REXROTH 7291-FD-09W27-MNR-3622312020 CONTROL PANEL
PRECIMA PRODUCTION AB-ROLLS-ROYCE-KAMEWA 1082 WATER JET CONTROL UNIT-2
PRECIMA PRODUCTION AB-ROLLS-ROYCE-KAMEWA 1082 WATER JET CONTROL UNIT-1
POUNDFUL PF-MF-3Q-3 TRANSMITTER MODULE
PLEIGER ELEKTRONIK 362-D 5810 WITTEN 3 CONTROL PANEL
PLEIGER EHS-CM CONTROL MODULE
PLEIGER EHS CM-2 CONTROL MODULE
PHONTECH DICS-6112 UNIT
PHOENIX CONTACT BLOMBERG GERMANY MINI MCR-2-UI-UI-PT 3-WAY SIGNAL CONDITIONER
PCS SYSTEME LAUER-PCS-200FZ CONTROL PANEL
PAN DELTA CONTROLS ENGINE TELEGRAPH EOT-706 CONTROL PANEL
PAN ASIA TOTAL INSTRUMENT & CONTROL MODEL-P940-P-I CONVERTER MODULE
NUNOTANI KEIKI TYPE-RE-S8A ELECTRIC PROPELLER SHAFT REVOLUTION COUNTER
NUNOTANI KEIKI PA-SPA K118 ELECTRIC PROPELLER SHAFT REVOLUTION INDICATOR CONTROL BOX
NORCONTROL LOS-LOCAL OPERATOR STATION CONTROL PANEL
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.