Description
IS220YDOAS1AJ General Electric Processor Board Mark VI
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
SH68-68-EP NI D-SUB Male
SDN20-24-100C SolaHD DIN guide power supply
PXI-8423 NI RS-485 Interface
PXI-7344 NI Stepper/Servo Motion Controller Module
PXI-6052E NI Multifunction DAQ Device
PXI-4472B NI PXI Sound and Vibration Module
PXI-2597 NI PXI RF Multiplexer Switch Module
PR6424003-030+CON021 EPRO eddy current displacement sensor
PR642310R-030-CN+CON021 EPRO Eddy Current Signal Converter
PPC-105T Advantech GX1 300 based Fanless Panel PC with 10″
PIB671-1500 ABB Advantage system metering board
PH266-01GK-C5 VEXTA 2-Phase Stepping Motor
PCS009 LAUER PCS 009 plus Operator Panel with MPI
PFXGP4501TADW display
PCI-6229 NI Multifunction I/O Device
PCI-6221 NI Multifunction I/O Device
P0912XX FOXBORO Transmitter actuator
P8 385RF-NG-SPT63-B HOERBIGER Solenoid valve
NPS-400AB B Fujitsu 470W Power Supply
NI-9227 NI C Series Current Input Module
MVME55006E-0161R Motorola VMEbus Single-Board Computer
MVME5500-0163 MOTOROLA VMEbus Single-Board Computer
MVIP302 Motorola IndustryPack Octal Serial Interface
MTR-3F-215 DEIF MULTI-TRANSDUCER W/ RS485 MODBUS
MTL5053 MTL POWER SUPPLY
MSK101D-0200-NN-M1-AG2-NNNN Rexroth MSK Synchronous Motors (复制)
MSK076C-0450-NN-M1-UG1-NNNN Rexroth MSK Synchronous Motors
MSK050C-0300-NN-M1-UG1-NNNN Rexroth MSK Synchronous Motors
MR-J2M-20DU Mitsubishi Melservo J2M Series
MRE-G128SP062FAC Nsd SENSOR,MULTI TURN
MN7234A2008 HONEYWELL DAMPER ACTUATOR 34NM 24V 0 TO 10
MKD090B-047-KG1-KN Rexroth MKD Synchronous Motors
ME203CN BACHMANN Processor Module
MKD071B-061-KP1-KN Rexroth MKD Synchronous Motors
MHD041B-144-PG1-UN Rexroth MHD Synchronous Motors
MKD071B-061-KG1-KN Rexroth servo motor
MCR-PSP-DC Phoenix Contact Alarm setting device
LSH-050-2-45-320T1.1R Lust LTi Drives
LS43.0124 EMG German sensor
LPQ172 Artesyn Embedded Technologies 4-output 175W open-frame AC/DC Power Supply
1X00416H01 EMERSON Process Management Power Supply
LNL-1320 Lenel Interface Module
LKB2211 SUPERRAC LKB Superrac Fraction Collector
KT3315TA Cutler-Hammer K-FRAME TYPE KT TRIP UNIT
KE310 REXROTH Electric Drives and Controls
KSY-464.80 R6XFWS113SB-1 GEORGII KOBOLD Ac Servo Motor
K0143AAAN FOXBORO Power supply module
JZNC-XRK01D-1 Yaskawa Framework of equipment
JANCD-XCP01-1 YASKAWA Central processing unit control board
JAMSC-B2902V Yaskawa MODULE PLC RELAY OUTPUT
ISH070/60017/0/0/00/0/00/10/00 SCHNEIDER SERVO MOTOR
IRDH375 BENDER Insulation monitoring device
IRDH275-435 BENDER Insulation monitoring instrument
HC703BS-E51 Mitsubishi Motors-AC Servo Motor
HA-SC23 Mitsubishi Motors-AC Servo
GV7-RS150 Schneider circuit breaker
WSWE24-2B230 SICK Compact photoelectric sensor
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.