Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
MTL838C MTL instrument analog transmitter
810-099175-011 LAM Interface board module
DSQC346G 3HAB8101-706B drive unit
5PC810. SX05-00 APC810 system unit
XV 430-12TSB-1-10 EATON 12.1″, TFT color
XV440-10TVB-X-13-1 EATON 10.4 “, TFT color
XV 430-10TVB-1-10 EATON 10.4 inches
XV442-57CQB-X-13-1 ESTON 5.7 inches
XV 432-57CQB-1-10 ESTON 5.7-inch touch screen
XV-440-12TVB-1-50 EATON
XV 440-12TSB-1-10 ESTON Touch panel
XV-440-12TVB-1-50 EATON Man-machine interface
XV 440-12TSB-X-13-1 ESTON 12.1″, TFT Color, i/r, Ethernet, USB, RS232, CANopen
XV442-57CQB-1-10 EATON 5.7 inch, Color, i/r, Ethernet, USB, RS232, CANopen
VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 MQ Controller
05074-A-0122 05704-A-0121 05704-A-0131 honeywell Quad Relay Interface Card
136294-01 BENTLY 3500/62 I/O Module
P0926PA FOXBORO FBM224, FBM230, and FBM231 terminals
VBX01TA ABB Bus Extender
F3430 HIMA Input/output module
P0916FK FOXBORO cable
140471-01 3500/42M I/O Module
F3430 HIMA Relay module F 3430
3500/91-01-01(161204-01+161216-01)bently Communication Gateway Module
LENZE EPL10200-W includes EPZ-10203 CANPT010W3E
UNS0119A-Z,V1 3BHE030579R0001 Automatic voltage regulator
UNITROL 1020 3BHE030579R0003 Indirect Excitation System
UNS0119A-Z,V1 3BHE030579R0001 Automatic voltage regulator
LAIB V3.0_A00 034STN1-01-300-RS
LAIB V3.0_A00 034STN1-00-300-RS
ATKB_V5.0_A01 03ZSTI4-01-501
ATKB_V5.0_A01 03ZSTI4-00-501
FPB_V3.0_A01 03ZSTJ1-00-301-RS
DSPB_V4.0_A02 03ZSTI7-00-402-RS
PUIM V2.0 034STM4-00-200-RS
DUDT_DETECTION_V2.0_A01 03ZSTJ0-00-201-RS
IPB PCB V2.0_A01 03ZSTL6-00-201-RS printed circuit board
IPB PCB V2.0_A01 03ZSTL6-00-201-RS printed circuit board
149992-01 BENTLY 3500/33 calories Relay Output Module
IS220PVIBH1A 336A4940CSP16 GE Vibration Monitor Pack
RH916XZ foxboro FBM247 Fieldbus module
IS420UCSCH2A-C-V0.1-A Four core controller GE
5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101
FROSOFT MVI56E-MNETXT Enhanced communication module
REXROTH HDS02.2-W040N-HS12-01-FW Servo controller
DEUBLIN 904-120-188
810-234640-312 LAM Printed circuit board
SAIA 52030C10 PCD2.W200 Analog input module
VM600 XIO16T 620-002-000-113 620-003-111-112 VM600 XIO16T
200-595-031-111 VM600 CPUM modular CPU card
VM600 MPC4 200-510-071-113 200-510-111-034 machinery protection module
VM600 XMV16 600-003 620-001-001-116 condition monitoring module for vibration
VM600 IOC4T 200-560-000-018 200-560-101-015 voltage-drop adaptor
VM600 XIO16T 620-002-000-113 620-003-111-112 extended condition monitoring modules
NI-9853 C series CAN interface module
Reviews
There are no reviews yet.