Sale!

PFCL201CD-10.0KN 3BSE029774R10 Модуль ввода / вывода ABB

Original price was: $1,888.00.Current price is: $1,688.00.

МодельPFCL201CD-10.0KN 3BSE029774R10

Первоначальная гарантия на один год.
PFCL201CD-10.0KN 3BSE029774R10 Параметры

PFCL201CD-10.0KN 3BSE029774R10 Размер 30 * 20 * 30
PFCL201CD-10.0KN 3BSE029774R10 Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

PFCL201CD-10.0KN 3BSE029774R10 Модуль ввода / вывода ABB
PFCL201CD-10.0KN 3BSE029774R10 Модуль ввода / вывода ABB
PFCL201CD-10.0KN 3BSE029774R10 Модуль ввода / вывода ABB Product details:
PFCL201CD-10.0KN 3BSE029774R10Поддержка одной платы связи и четырех разъемов IO; Поддерживает протоколы связи Modbus TCP, ProfiNet, EtherCAT, EtherNet / IP,

CC – Link и другие. Каждый слот IO может быть выбран автономно в соответствии с потребностями клиента, а один модуль поддерживает до 16 каналов.

Технологии основаны на инновацияхPFCL201CD-10.0KN 3BSE029774R10 Предоставление клиентам высококачественных и надежных продуктов всегда было постоянным стремлением к нулю.

Давайте посмотрим на его инновации и различия с предшественниками: с жидкокристаллическим дисплеем, вы можете увидеть параметры связи, состояние канала IO,

информацию о версии модуля и так далее; PFCL201CD-10.0KN 3BSE029774R10 Отладка и обслуживание более интуитивно понятны; ABS огнестойкая пластиковая оболочка, небольшой размер,

легкий вес, с использованием совершенно новой пряжки монтажной карты, установка более прочная и надежная.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

1SBP260020R1001 07CR41  ABB  Advant Controller Basic Unit
140A-C-ASA11A  Allen-Bradley  switch
AO610  ABB  Analog Output 16Ch
CM400RGICH1ACB  GE  Automation Module
DI651  ABB  Digital Input 32Ch
EP3-E-4-A  ALSTOM  MICRO CONTROLLER/ PROCESSOR
IB3110250  ELEMASTER
MRP528516 IS200EXHSG3AEC  GE  printed circuit board
MRP081636 IS200TSVCH1AJE GE
RF615  RC610 ABB I/O station with redundant CI610
UR6EH  GE  Digital I/O Input Output Module
X1052 DELL switch – 48 ports – Managed – rack-mountable
140DDO84300 Schneider DISCRETE OUTPUT MODULE
1756-BA2  Allen-Bradley  ControlLogix Lithium Battery
FBM222 P0926TL FOXBORO  Profibus DP Module
IC660TBA026M GE  Output block
IC660TBD024K  GE  DC 32 circuit discrete input and output
IOP351  METSO  control system
SB510 3BSE000860R1 ABB Backup Power Supply 110/230V AC
100031593.10  LSU-112DG  DEIF  load sharing units
R901325866  Rexroth Proportional Valve Solenoid Valve Hydraulic Valve
5600389 T8850 ICS Triplex  5600389 T8850
ZMU-02  ABB  FOR DEMO RACK
1FT5066-0AC71-2-Z  Siemens  Permanent magnet motor
223BD-00001AAB  MKS  Baratron Pressure Transducer
CB801 3BSE042245R1  ABB Profibus DP Communication Interface
3BHB003688R0001 ABB Module
REM615E_1G  ABB FEEDER PROTECTION AND CONTROL RELAY
CS513 3BSE000435R1 ABB  802.3 LAN-Module
136188-01 Bently Nevada  Communication Gateaway Module
3500/25 184684-01  Bently Nevada  Enhanced Keyphasor Module
3500/05-01-03-00-00-00 Bently Nevada  3500/05 System Rack
3500/44M 176449-03 Bently Nevada  Aeroderivitive GT Vibration Monitor
UR8FH  GE  Universal Relays of the UR Series
3500/32 125712-01  Bently Nevada  4-channel relay module
3500/40M 140734-01 Bently Nevada  Proximitor monitor I / O module
3500/40M 176449-01 Bently Nevada  Proximitor Monitor
3500/42M 176449-02  Bently Nevada  Proximitor/Seismic Monitor
125680-01 Bently Nevada  Proximitor I/O Module
CE4003S2B6 Emerson  Standard I/O Termination Block
F8620/11  HIMA  CPU Module
FS7-2173-2RP  HONEYWELL  FS7 Multispectral Fire and Flame Detector
IC698PSA100D GE  power supply module
PCI354-1022-38 02088-019  Jasper Electronics  Processor module

Reviews

There are no reviews yet.

Be the first to review “PFCL201CD-10.0KN 3BSE029774R10 Модуль ввода / вывода ABB”