Description
PFSA140 3BSE006503R1 Модуль ввода / вывода ABB
Швейцария, и входит в десятку крупнейших швейцарских транснациональных корпораций.PFSA140 3BSE006503R1
химическая, нефтехимическая, фармацевтическая, целлюлозно – бумажная, нефтепереработка; Оборудование приборов: электронные приборы, телевизоры и оборудование для передачи данных,
генераторы, гидротехнические сооружения; Каналы связи: интегрированные системы, системы сбора и распространения;PFSA140 3BSE006503R1Строительная промышленность: коммерческое и промышленное строительство.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
TB852 3BSC950263R1 ABB RCU Link Terminator
5SHX1445H0001 ABB semiconductor module
F8650X HIMA CPU Module
F8627X HIMA Ethernet Communication Module
F8627 HIMA Ethernet Communication Module
F8621A HIMA CPU Module
F7131 HIMA Power Supply Monitoring
F7126 HIMA Power Supply Module
VE3007 KJ2005X1-BA1 12P4375X012 MX Controller
TPMC815-11 TEWS ARCNET Interface Module
TC-4000-S ATLAS DC Controller QST
LDGRB-01 3BSE013177R1 ABB I/O Module
3500/92 136180-01 Bently Nevada Communication Gateaway Module
1756-ENBTA Allen-Bradley communication module
GF0-57CQD-002 OMACO MICRO PANEL
MPB2-TP Eaton VIDEO CARD
SY-60702001RA FOXBORO PLC Module
PPC-TB50 WATLOWANAFZE PROCESS CONTROL BOARD
ELMA 1900002919-0000R
133396-01 Bently Nevada Overspeed Detection I/O Module
3500-22M 138607-01 BENTLY Standard Transient Data Interface Module
3500-05-02-04-00-00-00 BENTLY DC IN Card Input Module
V4561983-0100 V4559856 ALSTOM PLC Module
API4380-G ABSOLUTE PROCESS INSTRUMENTS
60WKS-M24022 KOLLMORGEN SERVO CONTROL DRIVE
60WKS-CE240 22PB KOLLMORGEN SERVO CONTROL DRIVE
K3NX-AD1A-FLK4 OMRON sensor
FX-316 EMERSON Drive
1000554 EMERSON PC BOARD
IC693MDL231 GE Isolated Input Module
T9431 ICS TRIPLEX Analog Input Module
IS230TVBAH4A GE terminal board
AO2000-LS25 ABB Process analyzer
AO845 3BSE045584R1 ABB Analog Output
SCE904AN-002-01 Kollmorgen Performance Digital Servo Drive
8200-1312 Woodward Integrated Graphical Front Panel HMI Screen
SCYC51010 ABB Power Voting Unit
SPBRC400 ABB Controller with Expanded Memory
146031-01 Bently Nevada Transient Data Interface I/O Module
1900 65A 167699-02 Bently Nevada Operator Interface *max order 1
1900 65A-01-02-01-00-00 Bently Nevada General Purpose Equipment Monitor