Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
1783-BMS10CA managed Ethernet switch
VE4003S2B6 Analog input card
IC200UDR005 28-point mini PLC module
IC754VSI12CTD-EG Operation panel
VE4033S2B1 Redundant analog input card
8C-PDILA1 HONEYWELL control system switch module
NDCU-21C drive control unit 42000652 ABB
IC695ALG808 Isolates the analog output module
PLX31-EIP-MBS Modbus serial communication gateway
IC695ALG508 Isolates the RTD input module
PCIE-6351 Multifunctional I/O device
IC694MDL930 Relay output module
1756-L73XT/B ControlLogix-XT controller
DX61B0075-5A3-4-00 SEW servo drive
DS200IIBDG1AGA insulated gate bipolar transistor
E69F-TI2-JS current-pneumatic converter
VMIVME-4512 Analog I/O board
MC4/11/10/400 ELAU Motion controller
61866-15pt High performance industrial display
MTL5553 MTL Instrument isolator/Power supply
MTL838C MTL instrument analog transmitter
810-099175-011 LAM Interface board module
DSQC346G 3HAB8101-706B drive unit
5PC810. SX05-00 APC810 system unit
XV 430-12TSB-1-10 EATON 12.1″, TFT color
XV440-10TVB-X-13-1 EATON 10.4 “, TFT color
XV 430-10TVB-1-10 EATON 10.4 inches
XV442-57CQB-X-13-1 ESTON 5.7 inches
XV 432-57CQB-1-10 ESTON 5.7-inch touch screen
XV-440-12TVB-1-50 EATON
XV 440-12TSB-1-10 ESTON Touch panel
XV-440-12TVB-1-50 EATON Man-machine interface
XV 440-12TSB-X-13-1 ESTON 12.1″, TFT Color, i/r, Ethernet, USB, RS232, CANopen
XV442-57CQB-1-10 EATON 5.7 inch, Color, i/r, Ethernet, USB, RS232, CANopen
VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 MQ Controller
05074-A-0122 05704-A-0121 05704-A-0131 honeywell Quad Relay Interface Card
136294-01 BENTLY 3500/62 I/O Module
P0926PA FOXBORO FBM224, FBM230, and FBM231 terminals
VBX01TA ABB Bus Extender
F3430 HIMA Input/output module
P0916FK FOXBORO cable
140471-01 3500/42M I/O Module
F3430 HIMA Relay module F 3430
3500/91-01-01(161204-01+161216-01)bently Communication Gateway Module
LENZE EPL10200-W includes EPZ-10203 CANPT010W3E
UNS0119A-Z,V1 3BHE030579R0001 Automatic voltage regulator
UNITROL 1020 3BHE030579R0003 Indirect Excitation System
UNS0119A-Z,V1 3BHE030579R0001 Automatic voltage regulator
LAIB V3.0_A00 034STN1-01-300-RS