Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
LDGRB-01 3BSE013177R1 ABB I/O Module
3500/92 136180-01 Bently Nevada Communication Gateaway Module
1756-ENBTA Allen-Bradley communication module
GF0-57CQD-002 OMACO MICRO PANEL
MPB2-TP Eaton VIDEO CARD
SY-60702001RA FOXBORO PLC Module
PPC-TB50 WATLOWANAFZE PROCESS CONTROL BOARD
ELMA 1900002919-0000R
133396-01 Bently Nevada Overspeed Detection I/O Module
3500-22M 138607-01 BENTLY Standard Transient Data Interface Module
3500-05-02-04-00-00-00 BENTLY DC IN Card Input Module
V4561983-0100 V4559856 ALSTOM PLC Module
API4380-G ABSOLUTE PROCESS INSTRUMENTS
60WKS-M24022 KOLLMORGEN SERVO CONTROL DRIVE
60WKS-CE240 22PB KOLLMORGEN SERVO CONTROL DRIVE
K3NX-AD1A-FLK4 OMRON sensor
FX-316 EMERSON Drive
1000554 EMERSON PC BOARD
IC693MDL231 GE Isolated Input Module
T9431 ICS TRIPLEX Analog Input Module
IS230TVBAH4A GE terminal board
AO2000-LS25 ABB Process analyzer
AO845 3BSE045584R1 ABB Analog Output
SCE904AN-002-01 Kollmorgen Performance Digital Servo Drive
8200-1312 Woodward Integrated Graphical Front Panel HMI Screen
SCYC51010 ABB Power Voting Unit
SPBRC400 ABB Controller with Expanded Memory
146031-01 Bently Nevada Transient Data Interface I/O Module
1900 65A 167699-02 Bently Nevada Operator Interface *max order 1
1900 65A-01-02-01-00-00 Bently Nevada General Purpose Equipment Monitor
330780-50-00 Bently Nevada 3300 XL 11 mm Proximitor Sensor
330180-X0-05 Bently Nevada 3300 XL Proximitor Sensor
3500/92 Bently Nevada Communication Gateway
3500/42M Bently Nevada Proximitor Seismic Monitor
125840-02 Bently Nevada Low Voltage AC Power Input Module
330130-040-01-00 Bently Nevada 3300 XL Extension Cable
330106-05-30-10-02-00 Bently Nevada 3300 XL 8 mm Reverse Mount Probes
3500/44-01-00 Bently Nevada Aeroderivative Monitor
3500/33-01-00 Bently Nevada 16-Channel Relay Module
3500/25-01-01-00 Bently Nevada Enhanced Keyphasor Module
106M1081-01 Bently Nevada Universal AC Power Input Module
125720-01 Bently Nevada RELAY MODULE
125800-01 Bently Nevada Keyphasor I/O Module
135489-04 Bently Nevada I/O Module
133323-01 Bently Nevada Comms Gateway I/O Module
125840-01 Bently Nevada High Voltage AC Power Input Module
Reviews