Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
BENTLY ASSY78462-01U 78599-01A
TRICONEX ACM4609
TRICONEX 2000417
TRICONEX 2000418
TRICONEX 2101
TRICONEX 2290614
TRICONEX 2301
TRICONEX 2351
TRICONEX 2381
TRICONEX 3000763-110 2402
TRICONEX 2402
TRICONEX 2481
TRICONEX 3002
TRICONEX 3005
TRICONEX 3006
TRICONEX 3008 3000710-100
TRICONEX 3008
TRICONEX 3008N
TRICONEX 3101
TRICONEX 3201
TRICONEX 3301
TRICONEX AI3351
TRICONEX 3381
TRICONEX DO3401
TRICONEX RO3451
TRICONEX AO3481
TRICONEX 3481
TRICONEX 3501E
TRICONEX 3501TN2
TRICONEX 3502E
TRICONEX 3503E
TRICONEX 3511
TRICONEX 3515
TRICONEX 3601E
TRICONEX 3604E
TRICONEX 3607E
TRICONEX 3623T
TRICONEX 3625 D11A3NUT
TRICONEX 3625 D0810XJR
TRICONEX 3625 D0811EE2
TRICONEX 3625 I070PV1T
TRICONEX 3625 C080ZSK1
TRICONEX 3625 A10A07F7
TRICONEX 3625 D0811P20
TRICONEX 3625 C0810H1D
TRICONEX 3625 A091BHSD
TRICONEX 3625 D0811EDJ
TRICONEX 3625 D0810XJV
TRICONEX 3625 I070PV13
TRICONEX 3625 A10A07YZ
TRICONEX 3625 H070NMKW
TRICONEX 3625 D0811EDY
TRICONEX 3625 D0811EE8
TRICONEX 3625 D0811EE9
TRICONEX 3625 F11A47C2
TRICONEX 3625 F0914MYE
TRICONEX 3625 D0811EE0
TRICONEX 3625 A11A2U3K
TRICONEX 3625
TRICONEX 3625A
TRICONEX 3625C1
Reviews
There are no reviews yet.