Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
1756-CN2R/B Allen-Bradley communication module
1756-A7/B Allen-Bradley small and compact chassis
5X00622G01 Westinghouse Analog Input Card
5X00502G01 Westinghouse Analog output module
5X00500G01 Westinghouse Analog Input Module
5X00499G01 Westinghouse The 32-channel DI card is installed
5X00497G01 Westinghouse Base control unit
5X00226G01 Westinghouse I/O INTERFACE MODULE
5X00226G04 Westinghouse I/O Interface Module
5X00489G01 Westinghouse Power Distribution Module
5X00481G04 Westinghouse Processor Module
5X00106G01 Westinghouse High Speed HART Analog Input
1C31234G01 Westinghouse Compact Contact Input Module
1C31233G04 Westinghouse Analog Input Module
1C31232G02 Westinghouse Digital Input
1C31224G01 Westinghouse Analog Input Module
1C31227G01 Westinghouse 8 Channel Analog Input
1C31222G01 Westinghouse Relay Output Panel
1C31194G03 Westinghouse Control Module
1C31189G03 Westinghouse Speed Detector Module
1C31181G01 Westinghouse Remote I/O Master Unit
1C31179G01 Westinghouse Remote Input Output Master Attachment Unit
TPMC871-10 TEWS TPMC871-10 PMC Interface Module
T8461C ICS TRIPLEX T8461C Trusted TMR 24/48Vdc Digital Output Module
T8403C ICS TRIPLEX T8403C Trusted TMR 24Vdc Digital Input Module
IBA SM128V ABB Controller MODULE
F650BABF2G0LOSHE GE FEEDER MANAGEMENT RELAY
KJ3002X1-BF1 12P1732X042 EMERSON RTD Card
38B5786X132 EMERSON Single-Acting Direct Pneumatic Relay
PU515A 3BSE032401R1 ABB PU515A Real-Time Accelerator Exchange
PM866-2 3BSE050201R1 ABB Processor unit
CP405 A0 1SAP500405R000 ABB Control Panel 7″ TFT touch screen
330130-040-00-00 Bently Nevada 3300 XL Standard Extension Cable
330106-05-30-05-02-05 Bently Nevada 3300 XL 8 mm Reverse Mount Probes
330103-00-06-10-02-00 Bently Nevada 3300 XL 8 mm Proximity Probes
1785-L40C15 Allen-Bradley ControlNet PLC5 Programmable Logic Controller (PLC)
330103-00-04-10-02-00 Bently Nevada 3300 XL 8 mm Proximity Probes
A6110 EMERSON Protection Monitors
6ES7416-2FK02-0AB0 Siemens Processor Module
A6220 EMERSON Machinery Health Monitor
1785-CHBM Allen-Bradley hot-backup type of memory cartridge
CC-TAOX11 51308353-175 HONEYWELL Analog Output Module
CC-TDIL51 51307083-175 HONEYWELL Module
CC-TAIX11 51308365-175 HONEYWELL Analog Input IOTA Redundant
CC-TAIN11 51306515-175 HONEYWELL Redundant Analog Input Terminal Board
CC-PCNTOX 51308307-175 HONEYWELL Analog Output Module
CC-PFB401 51405044-175 HONEYWELL Fieldbus Interface Module
Reviews
There are no reviews yet.