Sale!

CC-TAIX11 Redundant power supply for C300

Original price was: $1,888.00.Current price is: $1,688.00.

Model:CC-TAIX11

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: CC-TAIX11
Brand: Honeywell
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
CC-TAIX11 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
CC-TAIX11 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: CC-TAIX11 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install CC-TAIX11 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating CC-TAIX11 to ensure proper use.
Product Introduction
CC-TAIX11 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?

Answer: 1. After the new machine is powered on for the first time.

2. Before making any modifications.

3. After completing the modification.

4. If the robot is important, conduct it regularly once a week.

5. It is best to make a backup on a USB flash drive.

6. Delete old backups regularly to free up hard drive space.

Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?

Answer: This is the intelligent periodic maintenance reminder of ABB robots.

Question 3: What should I do if the robot enters a system failure state when it is powered on?

Answer: 1. Restart the robot.

2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.

3. Restart.

4. If it still cannot be lifted, try B startup.

5. If it still doesn’t work, try P startup.

6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).

Question 4: Can robot backup be shared by multiple robots?

Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.

Five questions: What files can be shared in the robot backup?

Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.

Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?

Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.

Question 7: How to cancel the robot 50204 motion monitoring alarm?

Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.

2. Use the AccSet command to reduce the robot”s acceleration.

3. Reduce the v_rot option in the speed data.

Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?

Answer: 1. Select calibration in the ABB main menu.

2. Click ROB_1 to enter the calibration screen and select SMB memory.

3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.

4. Click “Close” when finished, then click “Update”.

5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”

Question 9: How to customize the speed of robot trajectory in the RAPID program?

Answer: 1. Select program data in the main menu of the teaching pendant.

2. After finding the data type Speeddata, click New.

3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.

4. The customized data can be called in the RAPID program.

Excitation system ABB module NKLM01-4
Excitation system ABB module NKEB02
Excitation system ABB module NKEB01
Excitation system ABB module NKDS01-100
Excitation system ABB module NKDO01-5
Excitation system ABB module NKDO01-2
Excitation system ABB module NKCS01-10
Excitation system ABB module NKCL01-7
Excitation system ABB module NKCL01-6
Excitation system ABB module NKCL01-33
Excitation system ABB module NKCL01-20
Excitation system ABB module NKCL01-10
Excitation system ABB module NKAS11-15
Excitation system ABB module NKAS11-12
Excitation system ABB module NKAS01-9
Excitation system ABB module NKAS01-8
Excitation system ABB module NKAS01-15
Excitation system ABB module NKAS01-13
Excitation system ABB module NKAS01-12
Excitation system ABB module NKAS01-11
Excitation system ABB module NKAS01-10
Excitation system ABB module NIS21
Excitation system ABB module NIRL03
Excitation system ABB module NIRL01
Excitation system ABB module NIPL01
Excitation system ABB module NIOX01
Excitation system ABB module NIOP02
Excitation system ABB module NINT-64
Excitation system ABB module NIMP02
Excitation system ABB module NIMP01
Excitation system ABB module NIMP01
Excitation system ABB module NIMP01
Excitation system ABB module NIMF02
Excitation system ABB module NIMF01
Excitation system ABB module NIDS01
Excitation system ABB module NIDO01
Excitation system ABB module NIDI01
Excitation system ABB module NICS01
Excitation system ABB module NICL01
Excitation system ABB module NIAO01
Excitation system ABB module NIAM02
Excitation system ABB module NIAM01
Excitation system ABB module NIAI05
Excitation system ABB module NIAI04
Excitation system ABB module NIAI03
Excitation system ABB module NIAI02
Excitation system ABB module NIAI01
Excitation system ABB module NIA001
Excitation system ABB module NHSS01
Excitation system ABB module NGCM02
Excitation system ABB module NGCM01
Excitation system ABB module NFTP01
Excitation system ABB module NFTP01
Excitation system ABB module NFCS01
Excitation system ABB module NFBA01
Excitation system ABB module NFAN02
Excitation system ABB module NFAN01
Excitation system ABB module NF93A-2
Excitation system ABB module Nextmove E100
Excitation system ABB module NE870 3BSE080239R1
Excitation system ABB module NDSO04
Excitation system ABB module NDSO03
Excitation system ABB module NDSO02
Excitation system ABB module NDSO01
Excitation system ABB module NDSM05
Excitation system ABB module NDSM04
Excitation system ABB module NDSM03
Excitation system ABB module NDSM02
Excitation system ABB module NDSM01
Excitation system ABB module NDSI02
Excitation system ABB module NDSI01
Excitation system ABB module NDLS03
Excitation system ABB module NDLS02
Excitation system ABB module NDLS01
Excitation system ABB module NDIS01

Reviews

There are no reviews yet.

Be the first to review “CC-TAIX11 Redundant power supply for C300”

Your email address will not be published. Required fields are marked *