Sale!

DS200FCRRG1A GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200FCRRG1A

Первоначальная гарантия на один год.
DS200FCRRG1A Параметры

DS200FCRRG1A Размер 30 * 20 * 30
DS200FCRRG1A Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

3.3 Design of computer control software

This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.

The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.

3.4 Design of touch screen software

The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.

3.5 Design of PLC software

As the core of this control system, PLC is mainly responsible for the following aspects:

Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.

Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.

It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.

Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface

3.6 Frequency converter settings

In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:

Switch the control mode to local control and set the inverter address according to the inverter user manual.

Set the inverter for remote control and select the communication mode.

Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.

Set the speed control mode of the inverter, such as speed control or torque control.

After completing the basic parameter settings, switch to the remote control state and wait for remote control.

4 Conclusion

This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

3BSE018125R1  communication module
CI853-1 communication module
3BSE018125R1 ABB communication module
CI853-1 ABB communication module
3BSE025347R1 control unit system
CI854 control unit system ABB
3BSE030221R1 control unit system ABB
CI854A control unit system ABB
3BSE030221R2 control unit system ABB
CI854A-EA control unit system ABB
3BSE018134R1 ABB communication module
CI855-1 ABB communication module
3BSE018106R1 control unit system ABB
CI855K01 control unit system ABB
3BSE018144R1 control unit ABB
CI857K01 control unit system ABB
3BSE018137R1 ABB Communication module
CI858-1 ABB communication interface unit
ABB control unit system 3BSE018135R1
ABB control unit system CI858K01
ABB control unit system 3BSE048845R2
ABB control unit system CI868K01-eA
ABB control unit 3BSE056767R
ABB control unit CI871K01
KUC711AE 3BHB004661R0001  ABB
KUC711AE101 3BHB004661R0101  ABB
KUC720AE 3BHB000652R0001  ABB
KUC720AE01 3BHB003431R0001 ABB
KUC720AE01 3BHB003431R0001 3BHB000652R0001
KUC755AE105 3BHB005243R0105   ABB
KUC755AE106 3BHB005243R0106  ABB
KUC755AE106 3BHB005243R0106   ABB
ABB  REF542PLUS SACE750090R0002
REF542PLUS 1VCR007346 ABB
REF542PLUS panel ABB
ABB REF610 1MRS050775
ABB REF610C11LCLR 60HZ relay
ABB REF615A_ 1G HAFNAEFCBGC1BQK11G
REF615A_ E HAFAABAAABE1BCA1XE
REF615C_ D HCFDACADAND2BNN1XD
ABB RREF615C_ C HCFFAEAGANB2BAN1XC
REF615C_ E HCFDACADABC2BAN11E
REF615E_ E HBFHAEAGNCA1BNN1XE

Reviews

There are no reviews yet.

Be the first to review “DS200FCRRG1A GE Mark VI”

Your email address will not be published. Required fields are marked *