Sale!

DS200PLIBG2ACA GE Steam Turbine System

Original price was: $1,888.00.Current price is: $1,688.00.

МодельDS200PLIBG2ACA

Первоначальная гарантия на один год.
DS200PLIBG2ACA Параметры

DS200PLIBG2ACA Размер 30 * 20 * 30
DS200PLIBG2ACA Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?

Answer: 1. After the new machine is powered on for the first time.

2. Before making any modifications.

3. After completing the modification.

4. If the robot is important, conduct it regularly once a week.

5. It is best to make a backup on a USB flash drive.

6. Delete old backups regularly to free up hard drive space.

Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?

Answer: This is the intelligent periodic maintenance reminder of ABB robots.

Question 3: What should I do if the robot enters a system failure state when it is powered on?

Answer: 1. Restart the robot.

2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.

3. Restart.

4. If it still cannot be lifted, try B startup.

5. If it still doesn’t work, try P startup.

6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).

Question 4: Can robot backup be shared by multiple robots?

Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.

Five questions: What files can be shared in the robot backup?

Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.

Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?

Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.

Question 7: How to cancel the robot 50204 motion monitoring alarm?

Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.

2. Use the AccSet command to reduce the robot”s acceleration.

3. Reduce the v_rot option in the speed data.

Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?

Answer: 1. Select calibration in the ABB main menu.

2. Click ROB_1 to enter the calibration screen and select SMB memory.

3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.

4. Click “Close” when finished, then click “Update”.

5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”

Question 9: How to customize the speed of robot trajectory in the RAPID program?

Answer: 1. Select program data in the main menu of the teaching pendant.

2. After finding the data type Speeddata, click New.

3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.

4. The customized data can be called in the RAPID program.

UNS 4684a-P V1 HIEE305144R0001 Board overvoltage protection
UNS 0017A-P HIEE305106R0001 Firing Unit
UNC 4674B HIEE305089R0001 I/O Interface Card
UA C096AE01 HIEE300794R0001 ANALOG INPUT/OUTPUT MODULE
HIEE300690R0001 AR C093 AE01 Relay Output Card
UF C092 BE01 HIEE300910R0001 Binary Input
UP C090 AE01 HIEE300661R0001 Binary Field Bus Coupler
HIEE205014R0001 UNC 4673A,V1 ABB Analog Measuring Card
UNC 4672A,V1  HIEE205012R0001 Analog Measuring Card
170M6496 HIER465095P0001 Thyristor fuse
HIER465095P0003 170M6501 Thyristor fuse
SPEZ 3BHS126938 3BHE013707R0002 Thyristor
UNC 4674B HIEE305089R0001 I/O Interface Card
UA C096AE01 HIEE300794R0001 ANALOG INPUT/OUTPUT MODULE
HIEE300690R0001 AR C093 AE01 Relay Output Card
UF C092 BE01 HIEE300910R0001 Binary Input
UP C090 AE01 HIEE300661R0001 Binary Field Bus Coupler
HIEE205014R0001 UNC 4673A,V1 ABB Analog Measuring Card
UNC 4672A,V1  HIEE205012R0001 Analog Measuring Card
170M6496 HIER465095P0001 Thyristor fuse
HIER465095P0003 170M6501 Thyristor fuse
SPEZ 3BHS126938 3BHE013707R0002 Thyristor
GDRM 42-133B-2 3BHE018893R0001 Fan 230V, 240W
UNS 3670, V2 HIEE205011R0002 Converter Electronics
MPS 10/5-230/24/48 3BHB006449R0001 ABB Power Pack
ABB KU C321 AE01 HIEE300698R0001 Power Pack
UA C326 AE 1 HIEE401481R0001 Combined I/O
PP C322 BE HIEE300900R0001 Processing Unit
ABB 3BHB028673R0010 PHASE MODULE FRAME 2 R0
ABB 2UBA001210R0130 PHASE MODULE FRAME 3 R0
ABB 2UBA001210R0040 PHASE MODULE 4MVA
DIODE ACS6000 3BHB044241R0001
61358064 DIODE ACS6000 Series
IGCT MODULE 3BHE023784R0001
3BHB020684R0001 IGBT Module
DIODE ACS1000 series 3BHL000398P0001
3BHL000397P0001 DIODE ACS1000 series
5SDD0760D0001 3BHL001862P0001 DIODE 38 MM / 6KV
3BHL000200P0001 5SDF0345D0006 DIODE PRESSP
5SDF 1045H0002 3BHL000986P3002 DIODE
5SHY 4045L0006 3BHB030310R0001 IGCT MODULE
5SHY 4045L0004 3BHB021400R0002 IGCT MODULE
5SHX 2645L0004 3BHL000389P0104
IGCT RC 3BHL000390P0104  5SHX 1960L0004
3BHL000387P0101 5SHX 1445H0002 IGCT MODULE
3BHL000391P0101 5SHX 1445H0001 IGCT MODULE
3BHB020538R0001 5SHX 1060H0003 RC-IGCT ACS5000 series
3BHL000392P0101 5SHX 1060H0001 IGCT MODULE
5SHX 0845F0001 3BHL000385P0101 IGCT MODULE ABB
3BHB018104R0001 5SHX 0660F0002 IGCT ACS5000
3BHB204520R0001 RECOVERY DIODE ACS6000
3BHL000396P0001 ACS1000 DIODE ABB
3BHE024577R0101 CONTROL BOARD AMC34 ABB
3BHB045647R0010 ACS1000 PM Kit for 14x 68mm IGCTs – GV C705 AE01
3BHB045647R0006 GV C714 A101 ACS5000 Series ABB
3BHE024415R0101 GATE DRIVER BOARD ABB
3BHB045668R0006 GV C713 A101 ACS1000 series IGCT
3BHB045647R0005 GV C713 A101 ABB 24x 51mm IGCT

Reviews

There are no reviews yet.

Be the first to review “DS200PLIBG2ACA GE Steam Turbine System”

Your email address will not be published. Required fields are marked *