Description
DS200TCDAG1B Reliable Turbine Control Solutions
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
Distinguished according to whether there is a position sensor, first of all, it is divided into sensing
and non-sensing. That is, whether Hall or other similar position sensors are used to sense the
position angle of the stator and rotor. In air pump applications, many use non-inductive control.
The excellent algorithm of through-hole is that after the motor is running, it detects the changes in
phase current to switch the phase current. In some heavy-duty or precise control applications,
sensory methods are used.
According to the three-phase power supply of the inverter, it can be divided into square wave control
and sine wave control. The square wave control strategy is simple, and the control process is direct
and effective. It adopts a six-step commutation strategy. The CPU modulates the PWM to drive the
power switch tube to generate a three-phase power supply that can run the motor. The control strategy
of sine wave is relatively complex, but the control effect is much better.
In sine wave control, there are two main control strategies.
One is direct torque control DTC Baidu Encyclopedia. The method is to calculate the estimated values
of motor flux and torque based on the measured motor voltage and current. After controlling the torque,
the motor speed can also be controlled. Direct torque control is a patent of the European ABB company. .
The second is, space vector control FOC Baidu Encyclopedia. Its essence is to equate an AC motor to a DC
motor, and independently control the speed and magnetic field components. By controlling the rotor flux linkage,
and then decomposing the stator current, the two components of torque and magnetic field are obtained. After
coordinate transformation, the normal motor is realized. handover or decoupling control.
During sine wave control, there are many derived more sophisticated control strategies, such as feedforward
control, maximum torque control, field weakening control, etc.
In the process of controlling the motor, there are multiple feedback control loops. When controlling the output
of the motor, there is a current loop; on this basis, there is a control loop that controls the speed; when a servo
motor is used, there is a position loop control.
Display operation panel DO802
Display operation panel DO802
Display operation panel DO801-eA
Display operation panel DO801 3BSE020510R1
Display operation panel DO801
Display operation panel DO801
Display operation panel DO801
Display operation panel DO630
Display operation panel DO620
Display operation panel DO620
Display operation panel DO610
Display operation panel DO210
Display operation panel DNC115
Display operation panel DLM02
Display operation panel DLM01
Display operation panel DL22N-22
Display operation panel DKL032
Display operation panel DIGIFAS7201
Display operation panel DIGIFAS7116
Display operation panel DIGIFAS7108
Display operation panel DIGIFAS7105
Display operation panel DI93a HESG440355R3
Display operation panel DI890
Display operation panel DI890
Display operation panel DI885
Display operation panel DI885
Display operation panel DI840-eA
Display operation panel DI840
Display operation panel DI831
Display operation panel DI831
Display operation panel DI830 3BSE013210R1
Display operation panel DI830
Display operation panel DI830
Display operation panel DI828-eA
Display operation panel DI825
Display operation panel DI825
Display operation panel DI821Z
Display operation panel DI821-eA
Display operation panel DI821
Display operation panel DI821
Display operation panel DI820-eA
Display operation panel DI820
Display operation panel DI820
Display operation panel DI818-eA
Display operation panel DI818
Display operation panel DI814-eA
Display operation panel DI814
Display operation panel DI814
Display operation panel DI814
Display operation panel DI811-eA
Display operation panel DI811
Display operation panel DI811
Display operation panel DI810-eA
Display operation panel DI810 3BSE008508R1
Display operation panel DI810
Display operation panel DI810
Display operation panel DI810
Display operation panel DI803-eA
Display operation panel DI803
Display operation panel DI803
Display operation panel DI802-eA
Display operation panel DI802
Display operation panel DI802
Display operation panel DI801-eA
Display operation panel DI801
Display operation panel DI801
Display operation panel DI801
Display operation panel DI801
Display operation panel DI724F
Display operation panel DI651
Display operation panel DI650 3BHT300025R1
Display operation panel DI650
Display operation panel DI620
Display operation panel DI610
Display operation panel DI581-S
Display operation panel DI524
Display operation panel DI210
Display operation panel DI04
Display operation panel DI01
Display operation panel DDO02
Display operation panel DDO01
Display operation panel DDI03
Display operation panel DDI01
Display operation panel DDC779CE102 3BHE027859R0102
Display operation panel DDC779CE102 3BHE027859R0102
Display operation panel DDC779BE02 3BHE006805R0002
Display operation panel DDC779BE02 3BHE006805R0002
Display operation panel DCS150-7E
Display operation panel DCP10
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.