hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
Control module DCS system spare parts NDSO03
Control module DCS system spare parts NDSO02
Control module DCS system spare parts NDSO01
Control module DCS system spare parts NDSM05
Control module DCS system spare parts NDSM04
Control module DCS system spare parts NDSM03
Control module DCS system spare parts NDSM02
Control module DCS system spare parts NDSM01
Control module DCS system spare parts NDSI02
Control module DCS system spare parts NDSI01
Control module DCS system spare parts NDLS03
Control module DCS system spare parts NDLS02
Control module DCS system spare parts NDLS01
Control module DCS system spare parts NDIS01
Control module DCS system spare parts NDIO-02
Control module DCS system spare parts NDCU-33CX 3AUA0000052751
Control module DCS system spare parts NDCU-12C NDCU-12CK
Control module DCS system spare parts NDCS03
Control module DCS system spare parts NDBU-95C
Control module DCS system spare parts NDBU-95C
Control module DCS system spare parts NCTM01
Control module DCS system spare parts NCPM01
Control module DCS system spare parts NCOM04
Control module DCS system spare parts NCOM03
Control module DCS system spare parts NCOM02
Control module DCS system spare parts NCOM01
Control module DCS system spare parts NCNA-01
Control module DCS system spare parts NCIS02
Control module DCS system spare parts NCIS01
Control module DCS system spare parts NBTM01
Control module DCS system spare parts NBRA-658C
Control module DCS system spare parts NBIO-21CU
Control module DCS system spare parts NBIO-21C
Control module DCS system spare parts NBIM02
Control module DCS system spare parts NBIM01
Control module DCS system spare parts NASO01
Control module DCS system spare parts NASM04
Control module DCS system spare parts NASM03
Control module DCS system spare parts NASM02S
Control module DCS system spare parts NASM02E
Control module DCS system spare parts NASM02
Control module DCS system spare parts NASM01
Control module DCS system spare parts NASI02/F
Control module DCS system spare parts NASI02
Control module DCS system spare parts NAOM01
Control module DCS system spare parts NAMU-01C 64702475D
Control module DCS system spare parts NAMM03
Control module DCS system spare parts NAMM02
Control module DCS system spare parts NAMM01
Control module DCS system spare parts NAIO-03
Control module DCS system spare parts NAIO-03
Control module DCS system spare parts NADS01
Control module DCS system spare parts MX-CS101-401
Control module DCS system spare parts MTB-01 3HNA006035-001
Control module DCS system spare parts MSR04XI
Control module DCS system spare parts MPRC086444-005
Control module DCS system spare parts MPRC086444-005
Control module DCS system spare parts MJFA9902
Control module DCS system spare parts MFS3N-230V
Control module DCS system spare parts MFPM02
Control module DCS system spare parts MFE460A033BW
Control module DCS system spare parts MEM86-3×192/CMBMR3
Control module DCS system spare parts MDO32BNS
Control module DCS system spare parts MDI32BIS
Control module DCS system spare parts MCOB-02 3HNE09204-1/03
Control module DCS system spare parts MCCB-02 3HNA001572-001
Control module DCS system spare parts MCB-02 3HNA018575-001
Control module DCS system spare parts MB810
Control module DCS system spare parts MB801V512
Control module DCS system spare parts MB510 3BSE044219DB
Control module DCS system spare parts MB510 3BSE002540R1
Control module DCS system spare parts MB510 3BSE002540R1
Control module DCS system spare parts MAI32LAD
Control module DCS system spare parts MAI32LAD
Control module DCS system spare parts M3AA80B2
Reviews
There are no reviews yet.