Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Vibro-meter VM600-ABE040 204-040-100-011 system racks
IS200EROCH1AED digital Signal processor control panel
IS200ERIOH1ACB excitation regulator I/O board
900CS10-00 Touch Screen
PLX31-EIP-MBS4 Ethernet /IP to Modbus Serial 4 ports
Honeywell 9211-ET-HN1 51154724-100 MODBUS/TCP firewall
VMIVME7750-734 VME printed circuit board
VME-7807RC-414001 single board computer
CC-TDOR01 digital output relay module
DC-TDOB01 51307186-275 Digital output module
S70602-NANANA digital servo driver
PDC235 3BHE032025R0101 Unitrol PC D235 exciter control module
3500/15-04-01 3500/15 AC power supply
3500/42-02-R0 Proximitor seismic monitor
3500/42-09-01 Proximitor earthquake monitor
3500/04-01 3500/04 Internal barrier grounding module
3500/42-09-00 Proximitor seismic monitor 3500/42M
KJ4001X1-BE1 Input/output carrier
VM600 IOCN 200-566-000-012 200-566-101-012 input/output card
3500/92-04-01-00 3500/92 Communication gateway
KJ3102X1-BA1 Security simulation input card
MVME177-003 single board computer
IC695PSA040F RX3i Power module
IS200TBCIH21CD Contact input terminal board
3500/53M-03-00 3500/53M Electronic Speed detection system
MVME162PA-252SE Embedded controller
8102-HO-IP GE 8-channel Analog Output
DEIF RMP-112D Power relay
DEIF GPU-3 generator protection unit
AAI543-H50 Analog output module
369-HI-R-M-0-0-H-E Series 369 motor management relay
IC660BRD025 Genius Modular redundant receive and output module
DSQC633C 3HAC043904-001/06 Measuring unit
2711P-T12C4A6 Man-machine interface (HMI) device
MSM031B-0300-NN-M0-CH0 servo motor
IC693CMM302L Genius communication module
140CPU42402 CPU interface support module
6KAVI43030Y1B2 GE 300i 30HP INVERTER DRIVE
5464-834 Speed sensor WOODWARD 5000 Modue Rev.A
5202-MNET-MCM4 ProLinx EtherNet/IP to Modbus Primary/secondary gateway
SSB401-53 ESB Bus Interface Slave Module
SAI143-H53 S2 Analog Input Module
PM571-ETH-V14x 1SAP130100R0270 Logic controller