Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
Excitation system ABB module DSDO308 57160001-LV
Excitation system ABB module DSDO305 57160001-CG
Excitation system ABB module DSDO304 57160001-U
Excitation system ABB module DSDO303 57160001-CS
Excitation system ABB module DSDO301 57160001-CC
Excitation system ABB module DSDO301
Excitation system ABB module DSDO140 57160001-DO
Excitation system ABB module DSDO131 57160001-KX
Excitation system ABB module DSDO131
Excitation system ABB module DSDO120 57160001-AX
Excitation system ABB module DSDO120 57160001-AK
Excitation system ABB module DSDO115A 3BSE018298R1
Excitation system ABB module DSDO115A
Excitation system ABB module DSDO115 57160001-NF
Excitation system ABB module DSDO110 57160001-K
Excitation system ABB module DSDO110
Excitation system ABB module DSDI454 57160075-Y
Excitation system ABB module DSDI453 57160075-AB
Excitation system ABB module DSDI452 57160075E
Excitation system ABB module DSDI452
Excitation system ABB module DSDI451 57160075A
Excitation system ABB module DSDI451
Excitation system ABB module DSDI306 57160001-CM
Excitation system ABB module DSDI304 57160001-DB
Excitation system ABB module DSDI303 57160001-CX
Excitation system ABB module DSDI301
Excitation system ABB module DSDI146 3BSE007949R1
Excitation system ABB module DSDI120AV1
Excitation system ABB module DSDI120
Excitation system ABB module DSDI110AV1/3BSE018295R1
Excitation system ABB module DSDI110AV1 3BSE018295R1
Excitation system ABB module DSDI110AV1
Excitation system ABB module DSDI110AU1
Excitation system ABB module DSD036S65U4031
Excitation system ABB module DSCS150
Excitation system ABB module DSCS140 57520001-EV/10
Excitation system ABB module DSCS131 57310001-LM
Excitation system ABB module DSCS131
Excitation system ABB module DSCS117
Excitation system ABB module DSCS116 57520001-BZ
Excitation system ABB module DSCS-116
Excitation system ABB module DSCS116
Excitation system ABB module DSCS115
Excitation system ABB module DSCQ315
Excitation system ABB module DSCL110A
Excitation system ABB module DSCL110
Excitation system ABB module DSCI112
Excitation system ABB module DSCG071S64U38-5
Excitation system ABB module DSCB-01C
Excitation system ABB module DSCA325
Excitation system ABB module DSCA310
Excitation system ABB module DSCA190V 57310001-PK
Excitation system ABB module DSCA190V
Excitation system ABB module DSCA180B
Excitation system ABB module DSCA180A
Excitation system ABB module DSCA170
Excitation system ABB module DSCA130
Excitation system ABB module DSCA-125A
Excitation system ABB module DSCA125A
Excitation system ABB module DSCA125
Excitation system ABB module DSCA124
Reviews