Sale!

HESG440940R11 HESG216791/A Interface Controller

Original price was: $1,888.00.Current price is: $1,688.00.

Model:HESG440940R11 HESG216791/A

New original warranty for one year

Brand: ABB

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: HESG440940R11 HESG216791/A
Brand: ABB
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
HESG440940R11 HESG216791/A is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
HESG440940R11 HESG216791/A is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: HESG440940R11 HESG216791/A Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install HESG440940R11 HESG216791/A correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating HESG440940R11 HESG216791/A to ensure proper use.
Product Introduction
HESG440940R11 HESG216791/A is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?

Answer: 1. After the new machine is powered on for the first time.

2. Before making any modifications.

3. After completing the modification.

4. If the robot is important, conduct it regularly once a week.

5. It is best to make a backup on a USB flash drive.

6. Delete old backups regularly to free up hard drive space.

Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?

Answer: This is the intelligent periodic maintenance reminder of ABB robots.

Question 3: What should I do if the robot enters a system failure state when it is powered on?

Answer: 1. Restart the robot.

2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.

3. Restart.

4. If it still cannot be lifted, try B startup.

5. If it still doesn’t work, try P startup.

6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).

Question 4: Can robot backup be shared by multiple robots?

Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.

Five questions: What files can be shared in the robot backup?

Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.

Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?

Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.

Question 7: How to cancel the robot 50204 motion monitoring alarm?

Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.

2. Use the AccSet command to reduce the robot”s acceleration.

3. Reduce the v_rot option in the speed data.

Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?

Answer: 1. Select calibration in the ABB main menu.

2. Click ROB_1 to enter the calibration screen and select SMB memory.

3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.

4. Click “Close” when finished, then click “Update”.

5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”

Question 9: How to customize the speed of robot trajectory in the RAPID program?

Answer: 1. Select program data in the main menu of the teaching pendant.

2. After finding the data type Speeddata, click New.

3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.

4. The customized data can be called in the RAPID program.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

Display operation panel 3HAC046686-002
Display operation panel 3HAC044168-001/00
Display operation panel 3HAC044168-001
Display operation panel 3HAC042766-001
Display operation panel 3HAC042593-001
Display operation panel 3HAC042591-001
Display operation panel 3HAC042590-001
Display operation panel 3HAC042589-001
Display operation panel 3HAC042587-001
Display operation panel 3HAC042584-001
Display operation panel 3HAC042580-001
Display operation panel 3HAC041843-001
Display operation panel 3HAC041443-003 DSQC639
Display operation panel 3HAC041443-003
Display operation panel 3HAC041325-001
Display operation panel 3HAC041317-001
Display operation panel 3HAC040658-001
Display operation panel 3HAC040657-001
Display operation panel 3HAC039993-002
Display operation panel 3HAC039429-001
Display operation panel 3HAC039428-001
Display operation panel 3HAC039307-004
Display operation panel 3HAC039307-003
Display operation panel 3HAC039302-001
Display operation panel 3HAC039289-005
Display operation panel 3HAC039289-003
Display operation panel 3HAC039245-003
Display operation panel 3HAC039137-001
Display operation panel 3HAC039109-002
Display operation panel 3HAC038889-001
Display operation panel 3HAC038767-001
Display operation panel 3HAC038557-001
Display operation panel 3HAC038556-001
Display operation panel 3HAC038555-002
Display operation panel 3HAC038555-001
Display operation panel 3HAC038554-002
Display operation panel 3HAC038554-001
Display operation panel 3HAC038553-004
Display operation panel 3HAC038553-002
Display operation panel 3HAC038553-001
Display operation panel 3HAC038547-001
Display operation panel 3HAC038460-001
Display operation panel 3HAC038458-001
Display operation panel 3HAC038377-001
Display operation panel 3HAC038212-002
Display operation panel 3HAC038210-005
Display operation panel 3HAC038210-004
Display operation panel 3HAC038210-003
Display operation panel 3HAC038174-061
Display operation panel 3HAC038002-001
Display operation panel 3HAC037947-001
Display operation panel 3HAC037820-002
Display operation panel 3HAC037820-001
Display operation panel 3HAC037778-002
Display operation panel 3HAC037778-002
Display operation panel 3HAC037778-001
Display operation panel 3HAC037639-002
Display operation panel 3HAC037639-002
Display operation panel 3HAC037639-001
Display operation panel 3HAC037638-004
Display operation panel 3HAC037638-003
Display operation panel 3HAC037638-002
Display operation panel 3HAC037638-002
Display operation panel 3HAC037635-003
Display operation panel 3HAC037635-001
Display operation panel 3HAC037559-004
Display operation panel 3HAC037550-001
Display operation panel 3HAC037314-001
Display operation panel 3HAC0373-1
Display operation panel 3HAC037281-001
Display operation panel 3HAC037210-002
Display operation panel 3HAC037192-003
Display operation panel 3HAC037114-001
Display operation panel 3HAC037084-001
Display operation panel 3hac037038-001
Display operation panel 3HAC036974-001
Display operation panel 3HAC036943-003

Reviews

There are no reviews yet.

Be the first to review “HESG440940R11 HESG216791/A Interface Controller”

Your email address will not be published. Required fields are marked *