Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
Excitation system ABB module XVC770BE101 3BHE021083R0101
Excitation system ABB module XVC770BE101 3BHE021083R0101
Excitation system ABB module XVC770BE101
Excitation system ABB module XVC770AE 3BHE006414R0001
Excitation system ABB module XVC770AE 3BHE006414R0001
Excitation system ABB module XVC769AE101 3BHE006373R0101
Excitation system ABB module XVC769AE101 3BHE006373R0101
Excitation system ABB module XVC769AE101 3BHE006373R0101
Excitation system ABB module XVC769AE101
Excitation system ABB module XVC769AE101
Excitation system ABB module XVC768AE117 3BHB007211R0117
Excitation system ABB module XVC768117 3BHB007211R117
Excitation system ABB module XVC768115 3BHB7211R115
Excitation system ABB module XVC768115 3BHB007211R115
Excitation system ABB module XVC768106 3BHB007211R106
Excitation system ABB module XVC768102 3BHB007211R102
Excitation system ABB module XVC768101 3BHB007211R101
Excitation system ABB module XVC767AE105 3BHB007209R0105
Excitation system ABB module XVC767AE105 3BHB007209R0105
Excitation system ABB module XVC767AE102 3BHB007209R0102
Excitation system ABB module XVC767AE102 3BHB007209R0102
Excitation system ABB module XVC724BE101 3BHE009017R0101
Excitation system ABB module XVC724BE101 3BHE009017R0101
Excitation system ABB module XVC724BE 3BHE009017R0102
Excitation system ABB module XVC722AE101 3BHB002751R0101
Excitation system ABB module XV9738a HEIE450617R
Excitation system ABB module XV9738a
Excitation system ABB module XTB750B01 HUCD420038R0001 HIEE440503P201
Excitation system ABB module XS321A-E
Excitation system ABB module XS321A
Excitation system ABB module XO08R2 1SBP260109R1001
Excitation system ABB module XO08R2 1SBP260109R1001
Excitation system ABB module XO08R2 1SBP260109R1001
Excitation system ABB module XO08R2
Excitation system ABB module XM06B5
Excitation system ABB module XI16E1
Excitation system ABB module VPM810
Excitation system ABB module VPM810
Excitation system ABB module VCD-02 3HNA006565-001
Excitation system ABB module VBX01T-VBX01B
Excitation system ABB module VBX01T-VBX01B
Excitation system ABB module VBX01TA
Excitation system ABB module VBX01TA
Excitation system ABB module VBX01BA
Excitation system ABB module VBX01BA
Excitation system ABB module VBS01-EPD
Excitation system ABB module VBS01
Excitation system ABB module V4550202-0100
Excitation system ABB module V17152-310
Excitation system ABB module V17152-310
Excitation system ABB module V17111-110
Excitation system ABB module UUD148AE02 3BHE014185R0002
Excitation system ABB module UUD148AE02
Excitation system ABB module UUD148AE01 3BHE014185R0001
Excitation system ABB module USC329AE01-1 3BHB002483R0001
Excitation system ABB module USC329AE01 3HB002483R0001
Excitation system ABB module USC329AE01 3BHB002483R0001
Excitation system ABB module USC329AE01
Excitation system ABB module UPC325AE01 3BHB000644R0001
Excitation system ABB module UNS4881b,V4 3BHE009949R0004
Excitation system ABB module UNS3670A-Z,V2 HIEE205011R0002
Excitation system ABB module UNS3020 HIEE205010R0003
Excitation system ABB module UNS3020 HIEE205010R0001
Excitation system ABB module UNS2980c-ZV4
Excitation system ABB module UNS2882A 3BHE003855R0001
Excitation system ABB module UNS2882A
Excitation system ABB module UNS2881B-PV1
Excitation system ABB module UNS2881b-P,V1 3BHE009319R0001
Excitation system ABB module UNS2880b-P,V2 3BHE014967R0002
Excitation system ABB module UNS2880B-P,V1
Excitation system ABB module UNS2880B-P
Excitation system ABB module UNS0887A-P 3BHE008128R0001
Excitation system ABB module UNS0885A-ZV1
Excitation system ABB module UNS0885a-Z V1 3BHB006943R0001
Excitation system ABB module UNS0884A-V1
Excitation system ABB module UNS0883a-P,V1
Excitation system ABB module UNS0881a-P,V1 3BHB006338R0001
Excitation system ABB module UNS0880a-P,V1
Excitation system ABB module UNS0874A
Excitation system ABB module UNS0868A-P HIEE305120R2
Excitation system ABB module UNS0867 A-P V2
Excitation system ABB module UNS0862A HIEE405179R0001
Excitation system ABB module UNS0122A-P
Excitation system ABB module UNS0119A-P,V101
Excitation system ABB module UNS0017A-P HIER464920P0001
Excitation system ABB module UNS0007A-PV1 HIEE305098R0001 HIEE410730P201
Excitation system ABB module UNS0007A-PV1
Excitation system ABB module UNITROL5000 3BHE017671R5000
Excitation system ABB module UNITROL1020
Excitation system ABB module UNITROL1010
Excitation system ABB module UNITROL1000 B-Z V104 3BHE014557R6104
Reviews
There are no reviews yet.