Description
IC752SPL013-BA Canopen Interface Module
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
6231BP10910 Redundant module ABB
IC660BBA104 Redundant module ABB
IC660BBA104 6231BP10910 ABB
3HNA024966-001/03 Robot spare parts ABB
HVC-02B Robot spare parts ABB
HVC-02B 3HNA024966-001/03 ABB
ABB HARMONY CONTROLLER HC800
ABB S+ HPC800K01 HARMONY CONTROLLER HC800
ABB S+ HPC800K02 HARMONY CONTROLLER HC800
HAC319AEV1 HIEE300771R1 ABB
HIEE300771R1 control module ABB
HAC319AEV1 control module ABB
3BHE039204P201REV.A control module
3BHE039203R0101 control module ABB
GVC736CE101 control module ABB
GVC736CE101 3BHE039204P201REV.A
GVC736CE101 3BHE039203R0101 ABB
GVC736CE101 3BHE039203R0101/3BHE039204P201 REV.A
GRBTU 3BSE013175R1 ABB
3BSE013175R1 control module ABB
GRBTU control module ABB
GOP2 control module ABB
GJR5252300R3101 07AC91H ABB
GJR5252300R3101 control module ABB
07AC91F control module ABB
GJR5252300R3101 control module ABB
GJR5252300R3101 07AC91F ABB
GFD233A103 control module ABB
3BHE022294R0103 control module ABB
GFD233A control module ABB
GFD233A 3BHE022294R0103 ABB
GFD212A 3BHE020356R0101/3BHE020357P201
GFD212A 3BHE020357P201 ABB
GFD212A 3BHE020356R0101 ABB
3BHE020357P201 control module ABB
3BHE020356R0101 control module ABB
GFD212A REV.E control module ABB
2UBA002322R0003 REV.E control module
2UBA002322R0001 control module ABB
GDD471A001 control module ABB
GDD471A001 2UBA002322R0003 REV.E
GDD471A001 2UBA002322R0001 ABB
GDD471A001 2UBA002322R0001/2UBA002322R0003 REV.E
GDD360C 3BHE047217R0101 ABB
3BHE047217R0101 control module ABB
GDD360C control module ABB
GDC806A0101 control module ABB
3BHE051592R0101/PCBREVB control module ABB
GDC801B101 control module ABB
GDC801B101 PCBREVB ABB
GDC801B101 3BHE051592R0101
GDC801B101 3BHE051592R0101/PCBREV:B ABB
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.