Sale!

IS200EDCFG1ADC General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200EDCFG1ADC

Первоначальная гарантия на один год.
IS200EDCFG1ADC Параметры

IS200EDCFG1ADC Размер 30 * 20 * 30
IS200EDCFG1ADC Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

MVI46-MCM  Modbus Master/Slave Network Interface Module
REF543KM127AAAA  ABB  Feeder terminal REF 543
GHG122  COOPER   Terminal Module
PHC21A-A022M1-E21A-00/S11   field inverter controller
PCD235A101 3BHE032025R0101  AC 800PEC  control system
3500/64M 140734-05  Bently Nevada  Dynamic Monitor
PCD230A101 3BHE022291R0101 AC 800PEC  control system
MINI-UTDE 10 BASE-T  Twisted pair Ethernet terminal
TPMC866-11  TEWS  8 Channel Serial Interface
DS2020FEXAG4  GE  VME Control Board
IS215UCVHM06A IS415UCVHH1A B  VME Control Board
IC697ALG440 GE   current expander module
IC697ALG230  GE  base converter module
IC697ACC720  GE Auxiliary Smart Battery Module
IC693MDL646  GE   positive / negative logic input module
IC693MDL640  GE  24 Volt DC positive logic input module
IC693CPU341  GE  single-slot CPU module
IC693CPU331  GE  Series 90-30 component
IC670MDL930K  GE  relay output module
IC670MDL740J GE  positive logic discrete output module
IC670MDL930J  GE  relay output module
IC693CMM321  GE  Ethernet interface module
IC670PBI001  GE  Profibus interface unit
IC693APU300K  GE  High-Speed Counter (HSC) module
IC670MDL740  GE  positive logic discrete output module
IC670MDL930  GE  relay output module
IC670MDL240K  GE  Sixteen channel discrete input module
IC670MDL640  GE  Discrete Input Module
IC670MDL241J  GE  discrete input module
IC670MDL644  24 Volts DC Positive/Negative Input Module GE
IC670MDL730  GE  DC Output Module
IC670MDL240J  GE Sixteen (16) channel discrete input module
IC670CPU350  series 90-30 controller  GE
IC670CHS101  I/O terminal block  GE
IC670CHS002  I/O terminal block  GE
IC660TSA100  GE  Terminal assembly
IC660ELD100A  GE  IC660 CBD100 I/O Block
IC660ELB912G  GE  µGENI Network Interface Board
IC660EBD020  electronics assembly  GE
IC200GBI001  VersaMax communication module  GE
IC660BBD025  GE  Block I/O from the Genius I/O Block series
IC200CHS001  Barrier-Style I/O Carrier manufactured  GE
1756-L62  Allen-Bradley  ControlLogix controller
1746-IA16 Allen-Bradley  SLC 500 Digital AC Input Module
IC695CRU320-EL  1 GHz CPU from the GE Fanuc RX3i PACSytems
330878-90-00  Bently Nevada   Proximitor Sensor