Sale!

IS200SSCAH2AGD GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200SSCAH2AGD

Первоначальная гарантия на один год.
IS200SSCAH2AGD Параметры

IS200SSCAH2AGD Размер 30 * 20 * 30
IS200SSCAH2AGD Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Implementation of communication between ABC industrial robot and PLC based on DeviceNet fieldbus technology
introduction

In modern production systems, industrial robots and PLCs need to communicate and collaborate to complete production tasks. That is, the
industrial robots output signals to the PLC, allowing the PLC to control related equipment to drive the robot”s front-end tools. This article
mainly analyzes the communication problems between ABB industrial robots and PLC based on DeviceNet fieldbus technology.
DeviceNet is a common network communication method in the field of automation. ABB industrial robots establish a network to communicate with
Siemens PLC based on the DeviceNet network.

1Configure DSQC652

There are mainly 5 types of standard I/0 boards commonly used in ABB industrial robots [2]. Except for the different addresses assigned to
them during setup, their configuration methods are basically the same. This article mainly analyzes the ABB standard I/0 board DS0C652, which
mainly builds communication modules based on the DeviceNet network. The DS0C652 board has a distributed I/O module with 16 digital input and 16
digital output interfaces. The board is installed in the ABB industrial robot control cabinet. First, define the specific operation steps of the DS0C652 board,
enter the teach pendant control panel, then enter the configuration menu (Figure 1), select the DeviceNetDevice menu, and add a template to enter Figure 2.
ABB standard I/0 board is hung on the DeviceNet
network, so the address of the module in the network must be set. The jumpers 6 to 12 of terminal x5 are used to determine the address of the module.
The available address range is 10 to 63. Modify the parameters in the template parameters to complete the DS0C652 board settings. Click the drop-down
menu to select the “Use value from template” row, select
“DS0C65224VDCI/0Device”, and then the parameters that need to be set include the address of the I/0 board in the bus.
Figure 1 Configuring DSQC652

2Configure signals and parameters

After completing the DS0C652 board setting, the I/0 signal setting will be performed. Setting the I/0 signal is the basis for establishing communication with
the PLC. The PLC communicates and transmits data with the ABB industrial robot through the I/0 signal and the DS0C652 board. As shown in Figure 3, in the
signal configuration interface, there are many default I/0 points after the system is established. Modification is not allowed. Click “Add” to add signals. When setting
input and output signals, their address range is 0~15. First, enter the signal menu in the configuration options to set the input and output types, and modify the corresponding parameters.
After completing the settings, the computer prompts that you need to restart the settings. If there are multiple signals that need to be defined and the waiting time
is long after restarting multiple times, you can click “Cancel” and wait for all signals to be defined before clicking the “Yes” button to restart. After the signal settings are
completed, click to select “Input and Output” in the ABB menu to check whether all signals have been set.
Figure 2 Configure DSQC652 parameters
Figure 3 Signal parameter settings

During the signal establishment process, attention should be paid to the DSoC652 port and PLC port addresses used, and the corresponding address table should be
established, as shown in Table 1. The robot interacts with the PLC through I/O signals. During the setting process, there must be no errors in the port and address number
of the PLC connected to the DSoC652. If the address is set incorrectly, the communication between the robot and the PLC will not work properly.

The entire robot teaching pendant setting process is shown in Figure 4.

489-P1-HI-A20-E GE Relay
489-P5-HI-A20-E  GE  Enhanced display
IS420ESWAH3A GE Ethernet switch
IS420ESWAH2A GE Ethernet switch
IS420ESWAH1A GE Control system
IS420YDOAS1B GE relay
IS420YAICS1B GE Analog input
IS420UCSDH1A GE processor
IS420UCSCH1C GE One of the UCSC controllers
IS420UCSCH1B GE  UCSC controller
IS420UCSBS1A GE Control safety system
IS420UCSBH4A GE High speed application
IS420UCSBH3A GE UCSB controller
IS420UCSBH1A GE controller
IS420UCPAH2A GE controller
IS420UCPAH1A GE processor
IS420PUAAH1A GE Universal input
IS420PSCAH1B GE  Communication module
IS420PPNGH1A GE Gateway module equipment
IS420PFFAH1A GE Bus gateway
IS420ESWBH5A GE Single mode fiber interface
IS420ESWBH4A GE ESWB IONet switch
IS420ESWBH1A GE IONet switch
IS420ESWAH5A GE  ESWA switches
IS420ESWAH4A GE  switch
469-P5-LO-A20-T GE Ethernet connection
469-P5-LO-A20-E  GE
469-P5-LO-A20 GE Low control power
469-P5-HI-A20-T-H GE Ethernet port
469-P5-HI-A20-T GE Ethernet communication
469-P5-HI-A20-E-H GE Output relay
469-P5-HI-A20 GE Motor management relay
469-P5-HI-A1-E GE  relay
469-P1-HI-A20-E-H GE
469-P1-HI-A1-E-H GE relay
469-P1-HI-A1-E GE Display screen
489-P5-LO-A20 GE Multiplex relay
SR469-P5-HI-A20-H GE  relay
SR469-P5-HI-A20-E GE Control power supply
SR469-P5-HI-A20 GE Analog output
469-P5-HI-A20-E  GE Control power supply
469-P1-HI-A20-E-H GE Analog output
369-LO-R-M-0-D-0-E GE Output relay
369-L0-R-M-0-D-0-E GE Enhanced motor
369-HI-R-M-F-0-H-E GE Relay
369-HI-R-M-F-0-H-E GE Motor protective relay
369-HI-R-M-0-0-H-0 GE Motor management relay
369-HI-R-M-0-0-0 GE Alternating current motor
369-HI-R-M-0-0 GE Resistance temperature detector
369-HI-R-B-0-E-0-E GE optically isolated
369-HI-R-B-0-0 GE Motor management
369-HI-R-0-F-0-0-E GE relay
369-HI-R-0-0-0-0-E GE relay

Reviews

There are no reviews yet.

Be the first to review “IS200SSCAH2AGD GE Mark VI”

Your email address will not be published. Required fields are marked *