Sale!

IS200STCIH6AED Exciter terminal board

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200STCIH6AED

Первоначальная гарантия на один год.
IS200STCIH6AED Параметры

IS200STCIH6AED Размер 30 * 20 * 30
IS200STCIH6AED Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

user experience

Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects

* cut costs

Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.

Implementation of communication between Omron vision system and ABB industrial robot

introduction

In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.

1Ethernet-based communication settings in vision software

The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.

First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.

After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.

2ABB industrial robot communication settings

First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.

Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.

DDC779CE102 3BHE027859R0102 ABB CPU module
ABB CSA464AE HIEE400106R0001 New original
CPM810 Common Processor Module
CMA123 Display Card ABB
CP800 ABB Communication processor module
CI854AK01 PROFIBUS-DP/V1 interface
APFS-11C ABB  POWER SUPPLY BOAR
3BSE038415R1 S800 I/O PLC AO810/AO810V2
AO810V2 Analog output module 3BSE038415R1
NEW AO810 Analog output module
AO810 Analog output 1×8 ch 3BSE008522R1
AI830A 3BSE040662R1 Analog input RTD 8 ch
ABB analog input module AI810 3BSE008516R1
AI810 Analog Input 8 ch 3BSE008516R1
NWE 5SHX1445H0001 3BHL000391P0101 3BHB003230R0101 5SXE05-0152
1TGE120021R0110 Communication Gateway
1TGE120011R1001 ABB Motor & Feeder Control Unit for MNS iS
X-AI3201 Analog Input Module X-AI 3201
Alcatel-Lucent  VSM-CCA-XP Versatile Services
Shinkawa VM-5G0-2 Dual vibration monitor
VE4005S1B3 i /O card
USB-6525 Digital I/O channel
TAP-210DG/3 TRANSDUCER INWATT
T8431 TMR 24Vdc Analogue Input Module
SYMAP-BCG Multifunctional protective relay
GLENTEK SMC9915-501-000-1D-1 Digital servo amplifier
Rexa SMB9215-1E-1-7725 Brushless servo amplifier
Alcatel-Lucent SFM2-200G MF Communications 7750 SR-SFM2-200G
SDAS-01-7Y2S1024 Current sensor Potter & Brumfield
SCXI-1193 NI RF Multiplexer Switch Module for SCXI
RH924YF Vertical-Mounted Baseplate
YOKOGAWA PW502 Power Unit
PCIE-5565PIORC-10000 Reflected memory PCI node card
P0926JM 8 Position Modular Baseplate
Foxboro P0926GH P0926GL-0C  I/A Series
ALCATEL-LUCENT OS9-GNI-C20L OmniSwitch 9000 Network Interface
NEW MXM402  Lyngso Marine Multiplexer Module
MVME5100 Emerson Single Board Computer
VME Processor Module MVME2432
KONGSBERG MRU-M-MB3 controller
EPRO MMS6120 Electric sensor module MMS 6120
EMG MCU24.2 Central processing unit
ELAU MC-4/11/22/400 Servo controller
HITACHI LYA010A Output module
PACIFIC LA23GCKC-1Y  Thimble seat motor
DeltaV emerson KJ3222X1-BA1 Analog Input Card
DeltaV emerson KJ3001X1-CB1 32-Channel DO Card
DeltaV emerson KJ3001X1-CA1 32-Channel DI module
ALCATEL IOM2-20G CPU Board
INDEL AG INFO-4KP-94161 Four-axis position control
PHOENIX ILB BT ADIO 2/2/16/16-4 Wireless module
Mitsubishi FX3U-4DA-ADP FX3U Analog output module
FOXBORO FBM230 P0926GU modbus Master (Serial and TCP/IP) Driver
FOXBORO FBM202 Analog input module FBM 202
1TGE120020R0405 ABB Compact Flash card
FOXBORO FBM06 Pulse Input Field Module FBM 06 P0400YG
F404002A Vista bus interface module INTERSCHALT
F7126 Power Supply Module F 7126
Molex DRL-DPM-BKF-B Network interface
MOOG D136-001-007 controller
KOKUSAI CXP-544 A-KOMS-A2 Time relay
Beckhoff  CP7002-0001-0010 Control Panel
NEW CC-PCNT01 C300 Controller Module Honeywell

Reviews

There are no reviews yet.