Sale!

IS220YDOAS1AJ General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS220YDOAS1AJ

Первоначальная гарантия на один год.
IS220YDOAS1AJ Параметры

IS220YDOAS1AJ Размер 30 * 20 * 30
IS220YDOAS1AJ Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

UFC911B108 3BHE037864R0108 Relay protection device
UFC911B106 3BHE037864R0106 Output module
UDD406A 3BHE041465P201 Input/output module
UCD208A101 3BHE020018R0101 Dc power supply
UAD154A 3BHE026866R0101 Ac power supply
TSXMRPC002M Configurable SRAM Memory Extension
TCSESM043F2CS0 Ethernet TCP/IP managed switch
SIOC 086406-002 SMART I/O CALIP ABB
SCXI-1326 SCXI Terminal Block
SCXI-1325 Screw Terminal Block
SCXI-1124 Analog Output Module for SCXI
SCXI-1100 Voltage Input Module for SCXI
SCM4.1 2044230022A 2044230020D  Signal processing module
PXI-8423 Interface for PXI
PFSK152 3BSE018877R2 3BSC980006R361 Signal concentrator board
PFSK151 3BSE018876R1 3BSC980006R358 DSP-Signal processing
PFEA112-65 3BSE050091R65 Tension Electronics PFEA112-65
IDEC PF3S-PSA2 POWER SUPPLY MODULE
PDD500A101 3BHE037649R0101 Communication module
PDD205A1121 3BHE025335R1121 Central processing unit
DEIF PCM4.3 2044230081A 2044230080A controller
PCIE-5565 PIORC-PCIE-5565 PIORC-100000-350 Reflection memory node interface card
3BHE025541R0101 PCD231B101excitation system
3BHE022291R0101 PCD230A  Excitation control system
P0926GH Channel communication terminal
GE VME Single-Board Computer MVME6100
MAESTRO 60X7/14 Servo Amplifiers
Y086388-001 LSP LINEAR STEPPER REPAIR
LCNP4E 51405098-100 digital power control board
IS230TBAIH2C Analog I/O Terminal Board
IS230TNCIH4C Printed Circuit Board
IS230SRTDH2A DIN RAIL MODULE
IS220PRTDH1A 363A4940CSP6 Input Module
IS220PPROS1B Emergency Turbine Protection I/O Pack
IS200SRTDH2ACB RTD Terminal Board
IS200DTAOH1ABA IS210DTAOH1AA DIN Rail Contact Input Board
IS200DTAIH1ACC IS210DTAOH1AA Printed circuit board
IS200DTAIH1ABB IS210DTAOH1AA Input/output terminal board
IOR810 PHBIOR80010000 Communication Module
IOM4.2 2044230041E 2044230040H Power control panel
IC698CPE030 microprocessor
GVC736CE101 3BHE039203R0101 5SXE12-0184 IGCT plate
GDD471A001 2UBA002322R0001 Printed circuit board
GCD207B101 3BHE024642R0101 Printed circuit board
FBM233 P0926GX Ethernet Communication
ABB ENK32 EAE Ethernet Module
ECPSR086370-001 Accuray Module
DS200ADGIH1AAA Auxiliary Interface Board
D685A1156U01 Backplane Type3+Housing FET
3500/22M 146031-01 Transient data interface module
3500/15 106M1081-01 AC/DC Power Supply Module
Transient Data Interface I/O Module 146031-01

Reviews

There are no reviews yet.

Be the first to review “IS220YDOAS1AJ General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *