Description
5 Fieldbus network layer
5.1 mfb (master field bus) bus
The mfb bus is a field LAN bus and is connected between mp200, mp90, s400i/o, OPC (small control station) and the transmission system.
The mfb communication bus uses coaxial cables and twisted pairs. It connects the ci520/ci525/ci526 communication interface module and the
dstc452 modem. The ends of each twisted pair must be isolated, and the shielding layer of one end must be grounded. The communication of mfb
The rate is 375kb/s, its resistance is 75 ohms, and its hardware configuration is shown in Figure 3. The relevant system information of mfb is obtained from
the engineering station. The general order is time, information model, code, task number, sequence number, and data. It mainly displays the following states.
Code 20: cpu communication interface contact lost
Code 21: fatal hardware failure
Code 39: device/staTIon ok
Code 72: device/statIon address ok
Code 120: Process failure
Code-1: Execution error
Code -4: System error
Code -5: Minor system site error
Code-6: Communication failure
Code-9: Catastrophic bus failure
Code -10: Redundant cable interrupted
5.2 af100 (advant field)/mb90 (master bus) bus
The purpose of AF100/MB90 is to provide communication between multiple APC sites or between APC sites and ABB industrial system equipment. MB90 supports two different types of communication,
data processing and information sending. The data set is dynamic data. Use To monitor and control a certain processing process, this process uses service information for parameterization, program installation,
and diagnosis. AF100/MB90 is a high-performance regional bus capable of connecting up to 79 APC sites. The mb90 has a maximum length of 300 meters, and if equipped with appropriate signal cables and signal repeaters,
and long-distance configurations between individual transmission devices are available, up to 2000 meters. Technical characteristics of the bus
(1) Communication rate 1.5mbit/s
(2) Attenuation bus length <300m, proliferation delay <2000m
(3) Telegram length 2, 4, 6, 8,…32 bytes of user data.
(4) Identification code (telegraph code) range 1…4000
(5) Cycle time 2, 4, 8, 16, 32, 64, 128…2048 or 4096ms
af100/mb90 relies on a centralized bus manager. The bus manager functions are relatively complex and have many requirements.
For example, apc sites cannot be used as bus managers because they do not contain bus manager functions. To make communication between APCs via
AF100/MB90 possible, each solution (standalone and embedded) can be used to arrange the bus master of AF100/MB90. When the APCs start executing
their applications, the bus master must be operable, otherwise the data set function block within the apc branch will enter an error state when the locally
configured data set is not acknowledged by the bus manager within the specified time limit. , if the system has only apc site and no masterpiece is connected to mb90 or ac450 and af100, an independent bus manager should be installed.
The communication between ABB DCS and the transmission system (such as acv700/dcv700) is realized by relying on the drrtra (drive trans mi t) element and drrec (drive reciver) element shown in Figure 4 .
The drrtra (drive transmit) element is used to pass a given data set to the abb drive controller and select the control word and command word signal of the drive signal.
The definition of the control word and command word signal is given in the application drive software description. The drrtr element can generate different types of periodic
messages supported by the drive communication protocol. The destination of the signal is selected by the drive signal. The drrtr element can also write parameters. In the normal phase, the overload of drrtr can be detected.
The drrec (drive reciver) element is used to receive signals and control word values from the abb drive controller. The definitions of these signals are given in the application drive software description. The drrec element is just periodic information supported
by the drive connection protocol. The receiving data source is selected by determining the drive signal and signal index through the element input parameters. The drrec element also has access to parameters, and overloads of drrec can be detected during configuration.
Display operation panel TPU3-EX 3HNA010905-001
Display operation panel TPSTU02
Display operation panel TPS02
Display operation panel TPPB-02 3HNA02320000101
Display operation panel TPPB-02 3HNA023200-001/01
Display operation panel TPM810
Display operation panel TPM01
Display operation panel TP910F
Display operation panel TP867 3BSE043664R1
Display operation panel TP867
Display operation panel TP867
Display operation panel TP858 3BSE018138R1
Display operation panel TP858
Display operation panel TP857 3BSE030192R1
Display operation panel TP857
Display operation panel TP854 3BSE025349R1
Display operation panel TP854 3BSE025349R1
Display operation panel TP854
Display operation panel TP854
Display operation panel TP854
Display operation panel TP853
Display operation panel TP853
Display operation panel TP852 3BSC950263R1
Display operation panel TP851
Display operation panel TP830
Display operation panel TP830
Display operation panel TMM-700
Display operation panel TK891F
Display operation panel TK891F
Display operation panel TK890F
Display operation panel TK890F
Display operation panel TK854V030
Display operation panel TK853V020
Display operation panel TK851V010/3BSC950262R1
Display operation panel TK850V007
Display operation panel TK831F
Display operation panel TK831F
Display operation panel TK821F
Display operation panel TK821F
Display operation panel TK817F
Display operation panel TK817F
Display operation panel TK812V150
Display operation panel TK812V050
Display operation panel TK812V050
Display operation panel TK812V015
Display operation panel TK812V015
Display operation panel TK811V150
Display operation panel TK811V150
Display operation panel TK811V050
Display operation panel TK811V050
Display operation panel TK811V015
Display operation panel TK811V015
Display operation panel TK811F
Display operation panel TK811F
Display operation panel TK809F
Display operation panel TK809F
Display operation panel TK808F
Display operation panel TK807F
Display operation panel TK807F
Display operation panel TK803V018 3BSC950130R1
Display operation panel TK802F
Display operation panel TK802F
Display operation panel TK801V012
Display operation panel TK801V012
Display operation panel TK801V006
Display operation panel TK801V006
Display operation panel TK801V003/3BSC950089R1
Display operation panel TK801V003
Display operation panel TK801V003
Display operation panel TK701F
Display operation panel TK527V030
Display operation panel TK516 3BSE000388R1
Display operation panel TK516
Display operation panel TK212A
Display operation panel TK212A
Display operation panel TK212
Display operation panel TK212
Display operation panel TD951F
Display operation panel TC630
Display operation panel TC625
Display operation panel TC562
Display operation panel TC560V2 3BSE022178R1
Display operation panel TC520 3BSE001449R1
Display operation panel TC514
Display operation panel TC512V1 3BSE018059R1
Display operation panel TC512V1
Display operation panel TC512
Display operation panel TC405K03
Display operation panel TBU810
Display operation panel TB870F
Display operation panel TB870F
Display operation panel TB852
Display operation panel TB852
Display operation panel TB850 3BSC950193R1
Display operation panel TB850
Display operation panel TB850
Display operation panel TB845
Display operation panel TB842
Display operation panel TB840A 3BSE037760R1
Reviews