Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3Configuring Siemens PLC
For PLC, Siemens S-1200PLC is used. Siemens PLC needs to be configured and programmed in Botu software.
After the program
is completed, the communication settings between the robot and PLC can be set. First, select the device and
network in the Porto software, then add a new device and select the controller model as Siemens 1212, as shown
in Figure 5. After adding the device, you need to set up
the PLC network. The computer and PLC must set corresponding IP addresses in the same network segment to
facilitate downloading and uploading PLC programs. After the settings are completed, click on the project tree
on the left to select the program block, and then enter
program writing. After the entire program is written, you can check whether the robot has received the signal from
the PLC through the input and output menu call in the ABB industrial robot teaching pendant, or you
can check online whether the PLC has received the signal from the
robot through the Botu software. When the line connection is good, the operator can set some signals to
complete the test work. If the test communication is normal, further PLC programming can be performed.
Figure 5 Botu software configures new equipment
4 Conclusion
This article explains in detail the communication setting process between ABB industrial robots and Siemens
PLC, making full use of the characteristics of industrial fieldbus technology. During the communication process
, signal settings are based on DeviceNet fieldbus technology. The actual operation verifies the content described
in this article. feasibility. In communication settings, special attention should be paid to the process of setting parameters such as address signals. Based on
DeviceNet fieldbus technology, communication between ABB industrial robots and PLCs can be completed more
quickly and conveniently.
In modern industry, the communication technology between industrial robots and PLC has improved the level
of production line automation and can better utilize the flexible and expandable characteristics of industrial robots.
Therefore, it is foreseeable that the application of communication technology in the production line will continue to
increase, thus exerting a great influence on industrial production. greater effect.
3BDH000383R0005 DX722F Digital input/output module
3BDH000387R0005 DX731F Digital input/output module
3BDH000371R0005 DA701F Digital/Analog module
3BE066485R1 PM851AK01 Processor unit
3BE069449R1 CI854BK01 PROFIBUS-DP/V1 port
3BSE020512R1 AI801 Analog Input 8 channels
3BSE020514R1 AO801 Analog output 8 channels
3BSE020508R1 DI801 Digital input 24V 16 channels
3BSE020510R1 DO801 Digital output 24V 16 channels
3BSE013208R1 TB820V2 Modulebus Cluster modem
3BSE008508R1 DI810 Digital input module
3BSE020836R1 DI840 Redundant digital input module
3BSC690073R1 DI890 The digital input module is intrinsically secure
3BSE008510R1 DO810 Digital output module Transistor type
3BSE020838R1 DO840 Redundant digital output module transistor type
3BDH000530R1 PM803F Base Unit 16 MB
3BDH008381R0001 TU732F Input/output terminal device
3BSE076940R1 PM 862K01 Processor Unit -67MHz and 32MB.
3BSE092689R1 CI 867AK01 Modbus TCP interface
MU-CTVF11 HONEYWELL Vertical Trim Panel Set – Full Height
MU-CTVH11 HONEYWELL Vertical Trim Panel Set – Half Height
MU-SMAC02 HONEYWELL Analog Output Standby Manual
MU-SMDC02 HONEYWELL Digital Output Standby Manual
MU-KSX152 HONEYWELL SDISI FTA EIA – 485 Cable
MU-MASX02 HONEYWELL Manual/Auto Station
MU-MASX02 HONEYWELL Manual/Auto Station
MC-TSIA12 HONEYWELL MU-TSIA12 Serial Interface FTA for Allen-Bradley
MC-TSIM12 HONEYWELL MU-TSIM12 Serial Interface FTA for Modbus
MC-TSDU02 HONEYWELL MU-TSDU02 Serial Device Interface FTA for UDC 6000
MC-TSDM02 HONEYWELL MU-TSDM02 Serial Device Interface FTA for Manual/Auto Station
MC-TSDT02 HONEYWELL MU-TSDT02 Serial Device Interface FTA for Toledo Scale
PCI-7813R Digital reconfigurable I/O devices
MC-TDOY63 HONEYWELL MU-TDOY63 Digital Output Relay FTA (16 Outputs)
MC-TDOY62 HONEYWELL MU-TDOY62 Digital Output 24 Vdc FTA (32 Outputs)
MC-TDOR62 HONEYWELL MU-TDOR62 Digital Output 240 Vac/125 Vdc Relay FTA
MC-TDOR52 HONEYWELL MU-TDOR52 Digital Output 120 Vac/125 Vdc Relay FTA
MC-TDOD62 HONEYWELL MU-TDOD62 Digital Output 5-200 Vdc Solid State
Reviews
There are no reviews yet.