1. introduction
abb dcs is a distributed control system designed and developed by Swiss Asea Brown Boveri Company (abbreviated as abb company). It has a wide range of applications and can be used in discrete manufacturing industries , such as machine tools, automobiles, aircraft manufacturing and other industries, as well as in large and medium-sized enterprises. Small-scale continuous production process industries, such as petroleum, chemical industry, thermal power units, steelmaking, building materials and other industries. abb dcs system adopts international standards from hardware design to software design and communication. The software programming language ampl (asea mas ter pi ece language) of abb dcs is a programming mode of the control system. This article introduces the architecture of abb dcs and its fieldbus network.
2 abb dcs distributed industrial control computer system architecture
abb dcs distributed control system uses advanced microprocessors (33mhz motorola 68020 and 33mhz intel 80386, 80486 chips), crt graphic display technology, high-speed safety communication technology and modern control theory to form an on-site control station (mp200, ac410 , ac450 series and local and remote i/o series), operator station (as500 series), engineer station (master ai d series), information management system station (advant station series ), computer and network interface station (master gate series), computer network (master bus series) and other computer communication equipment, it is a large-scale intelligent network with dispersed physical locations, dispersed system functions, dispersed control functions, and centralized operation display management for process control and process decision-making management. The communication network structure of abb dcs is divided into three layers:
3 Information Management Network Layer
It can be connected to 9 control networks. The network is composed of type mb300 bus, and the bus transmission rate reaches 10mbps.
4 Control network layer
The control network layer consists of 9 buses of type mb300. A control network may include 99 stations (including stations in local control networks). Each mp200/1 or ac450 station in the control network can be connected to a local control network. A local control network can include 9 buses of type mb300. mb300 is a high-performance, serial, synchronous, half-duplex high-speed bus with large data volume. It adopts ieee 802.2 logical link control (llc) protocol and ieee 802.3 carrier frame listening multiple access with conflict detection (csma/cd) media access control (mac) protocol. It is an ethernet type LAN and the bus can carry loads . 45 nodes. When no repeater is used, the maximum communication node distance is 500m; when using 3 coaxial segments, 4 repeaters and 2 point-to-point links, the maximum communication node distance is 2500m, and the bus transmission rate is 10mbps.
mb300 realizes the connection to the host computer and communication with PLC systems such as MP200 through each node . It generally follows the 543 rule, that is, it is composed of 5 sections and 4 repeaters (repeater) connections, 3 of which can be connected to equipment. It must be noted that only the marked prescription of the cable can be connected through the transceiver ( tranceiver ) Equipment, different equipment connections use different connection cables, such as tk526 cable to the pu510 operating station, and tk576 cable to the control station. The tranceiver can only be installed at the 2.5-meter mark on the main cable section. The spacing between the tranceivers on the coaxial cable section between the two line joints should be an integer multiple of 25 meters. The connection method is as shown in the figure.
t1 and t2 are terminal resistors . As long as one end is grounded, the terminal resistance is 50 ohms. The mb300 bus is a coaxial cable. It is divided into thick cable, thin cable and optical cable. Their functions are different. When laying the coaxial cable, you need to pay attention to it. Isolation from other signal cables, such as 30cm away from signal cables, 50cm away from 380v low-voltage cables, and 5m away from high-voltage cables. The mb300 bus uses the cs513 interface card. The three dial switches s1, s2, and s3 are used to set the network number, node number, and protocol number respectively. The low four bits of s1 are used to set the master/slave station selection. The high four bits are used to set the protocol number, s2 is used to set the node number, and s3 is used to set the network number. When it is necessary to modify or find out the cause of the fault through fault information, you can enter the engineering station to modify the data or know the fault location of the mb300 bus through the fault code. Understand the communication factors that affect mb300 and analyze these factors one by one.
Excitation system ABB module EI813F
Excitation system ABB module EI813F
Excitation system ABB module EI813F
Excitation system ABB module EI813F
Excitation system ABB module EI812F-Z
Excitation system ABB module EI812F
Excitation system ABB module EI812F
Excitation system ABB module EI811F-Z
Excitation system ABB module EI811F
Excitation system ABB module EI811F
Excitation system ABB module EI803F
Excitation system ABB module EI803F
Excitation system ABB module EI802F
Excitation system ABB module EI801F
Excitation system ABB module EHDB280-21-11
Excitation system ABB module EHDB280
Excitation system ABB module EHDB280
Excitation system ABB module EHDB220-21-11
Excitation system ABB module EHDB130
Excitation system ABB module EHDB130
Excitation system ABB module EH450C-1
Excitation system ABB module E5EAA HENF105240R1
Excitation system ABB module E3ES
Excitation system ABB module E3EP HENF315276R1
Excitation system ABB module E3EFa HENF452750R1
Excitation system ABB module E3EC HENF315125R1
Excitation system ABB module E3EB HENF315129R1
Excitation system ABB module DX910S
Excitation system ABB module DX910S
Excitation system ABB module DX910N
Excitation system ABB module DX910B
Excitation system ABB module DX731F
Excitation system ABB module DX722F
Excitation system ABB module DX581-S
Excitation system ABB module DSVC113
Excitation system ABB module DSU462
Excitation system ABB module DSU461
Excitation system ABB module DSU451
Excitation system ABB module DSU45
Excitation system ABB module DSU223
Excitation system ABB module DSU14
Excitation system ABB module DSU14
Excitation system ABB module DSU10
Excitation system ABB module DSU10
Excitation system ABB module DSTYW121 3BSE007836R1
Excitation system ABB module DSTXN001-0
Excitation system ABB module DSTX170
Excitation system ABB module DSTX152
Excitation system ABB module DSTX151
Excitation system ABB module DSTX150
Excitation system ABB module DSTX001
Excitation system ABB module DSTV110
Excitation system ABB module DSTS106 3BSE007287R1
Excitation system ABB module DSTS105 3BSE007286R1
Excitation system ABB module DSTS104 3BSE007285R1
Excitation system ABB module DSTK179
Excitation system ABB module DSTK176
Excitation system ABB module DSTK155
Excitation system ABB module DSTK152
Excitation system ABB module DSTK151V
Excitation system ABB module DSTK126
Excitation system ABB module DSTK114
Excitation system ABB module DSTD-W150
Excitation system ABB module DSTDN001
Excitation system ABB module DSTD310
Excitation system ABB module DSTD306
Excitation system ABB module DSTD160
Excitation system ABB module DSTD155